Document revision history, Document revision history -1 – Altera Integer Arithmetic IP User Manual
Page 156

Document Revision History
13
2014.12.19
UG-01063
The following table lists the revision history for this document.
Table 13-1: Document Revision History
Date
Version
Changes
December, 2014
2014.12.19 • Removed the LPM_ADD_SUB and LPM_COMPARE IPs
because these IPs are no longer supported.
• Added a note to clarify that when building multipliers larger
than the natively supported size there may be a performance
impact resulting from the cascading of the DSP blocks in LPM_
MULT, ALTERA_MULT_ADD, ALTMULT_ACCUM,
ALTMULT_ADD, and ALTMULT_COMPLEX IP cores.
• Added information about the Create a ‘sync_e’ port parameter
and the
sync_e
signal for ALTECC_DECODER IP core.
• Removed
sconst
port information as the port is no longer
available for LPM_COUNTER IP core.
• Provided an example to use the LPM_HINT parameter.
August, 2014
2014.08.18 • Updated parameterization steps for legacy and latest parameter
editors.
• Added note for IP cores that do not support Arria 10 designs.
• Added device migration information.
June 2014
5.0
• Replaced MegaWizard Plug-In Manager information with IP
Catalog.
• Added standard information about upgrading IP cores.
• Added standard installation and licensing information.
• Removed outdated device support level information. IP core
device support is now available in IP Catalog and parameter
editor.
June 2013
4.0
• Added
ALTERA_MULT_ADD (Multiply-Adder)
on page 6-1
section.
• Removed the following obsoleted megafunctions: LPM_ABS,
ALTACCUMULATE, ALTMULT_ACCUM, ALTMULT_
ADD,
©
2014 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, ENPIRION, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words and logos are
trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other words and logos identified as
trademarks or service marks are the property of their respective holders as described at
www.altera.com/common/legal.html
. Altera warrants performance
of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any
products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information,
product, or service described herein except as expressly agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device
specifications before relying on any published information and before placing orders for products or services.
www.altera.com
101 Innovation Drive, San Jose, CA 95134