Error detection, Verifying error detection functionality, Error detection -8 – Altera MAX 10 FPGA User Manual
Page 38: Verifying error detection functionality -8

• To program any of the CFM0/CFM1/CFM2 only, select the corresponding CFM in the Program/
Configure column.
• To program the UFM only, select the UFM in the Program/Configure column.
• To program the CFM and UFM only, select the CFM and UFM in the Program/Configure column.
Note: ICB setting is preserved in this option. However, before the programming starts, Quartus II
Programmer will make sure the ICB setting in the device and the ICB setting in the
selected
.pof
are the same. If the ICB settings are different, Quartus II Programmer will
overwrite the ICB setting.
• To program the whole internal flash including the ICB settings, select the
in the
Program/Configure column.
7. To enable the real-time ISP mode, turn-on the Enable real-time ISP to allow background program‐
ming.
8. After all settings are set, click Start to start programming.
Accessing the Remote System Upgrade Block Through User Interface
The following example shows how the input and output ports of a WYSIWYG atom are defined in the
MAX 10 device.
fiftyfivenm_rublock
(
.clk(
.shiftnld(
.captnupdt(
.regin(
.rsttimer(),
.rconfig(),
.regout(),
);
defparam
defparam
defparam
Related Information
Remote System Upgrade Circuitry Signals
on page 2-10
Provides more information about remote system upgrade signals.
Error Detection
This section covers detailed guidelines on error detection.
Verifying Error Detection Functionality
You can inject a soft error by changing the 32-bit CRC storage register in the CRC circuitry. After
verifying the failure induced, you can restore the 32-bit CRC value to the correct CRC value using the
same instruction and inserting the correct value. Be sure to read out the correct value before updating it
with a known bad value.
3-8
Accessing the Remote System Upgrade Block Through User Interface
UG-M10CONFIG
2015.05.04
Altera Corporation
MAX 10 FPGA Configuration Design Guidelines