Power up, Instant-on – Altera MAX 10 FPGA User Manual
Page 28
Related Information
.pof Generation through Convert Programming Files
on page 3-6
Provides more information about how to set th weak pull-up during configuration.
Power Up
If you power-up a device from the power-down state, you need to power the V
CCIO
for bank 1B and 8 to
the appropriate level for the device to exit POR.
To begin configuration, the required voltages must be powered up to the appropriate voltage levels as
shown in the following table. The V
CCIO
for bank 1B and bank 8 must be powered up to a voltage between
1.5V – 3.3V during configuration.
Table 2-19: Single-Supply and Dual-Supply Voltage Requirements for MAX 10 Devices
Power Supply Device Options
Voltage that must be Powered-Up
Single-supply
Regulated V
CC_ONE
V
CCA
V
CCIO
bank 1B and bank 8
Dual-supply
V
CC
V
CCA
V
CCIO
bank 1B and bank 8
Related Information
•
Provides more information about power supply modes in MAX 10 devices
•
Provides more information about the ramp-up time specifications.
•
Provides more information about configuration pin connections.
Instant-on
The MAX 10 devices support instant-on feature. The instant-on mode is the fastest power-up mode for
MAX 10 devices.
If you enable instant-on, the device will directly enter the configuration stage. The POR delay value will be
used to delay the POR signal if the instant-on feature is not enabled.
Table 2-20: Instant-On Power Up Sequence Requirement for MAX 10 Devices
Power Supply Device Options
Power Up Sequence
Single-supply
V
CCIO
must ramp up to full rail before V
CCA
and V
CC_ONE
start ramping
Dual-supply
All power supplies must ramp up to full rail before V
CC
starts ramping
2-24
Power Up
UG-M10CONFIG
2015.05.04
Altera Corporation
MAX 10 FPGA Configuration Schemes and Features