than the total number of signaling links supported.
already have been configured using the MTP_LINKSET command.
range 0 to one less than the number of links in the link set.
link set and is usually the same as the
The index of the signaling processor (within the board) allocated for this
signaling link. It must be in the range 0 to one less than the number of
signaling processors on the board.
logical identity of the T1/E1 line interface (liu_id) containing the signaling link
It must be in the range 0 to one less than the number of line interfaces.
Note: For the SPCI2S, stream identifiers for the PCM interfaces are implemented on
streams 2 and 3.
valid range is 1 ... 31. For a T1 interface the valid range is 1 ... 24. When set
to zero the signaling path through the board must be set up manually using
the switch control messages.
Bit 0 is set to 1 to force the use of the emergency proving period during link
alignment or zero to use the appropriate proving period according to the
MTP3 recommendations.
Bit 1 is set to 1 to cause a signaling link test (in accordance with ITU-T Q.707
/ ANSI T1.111.7) to be carried out before a link is put into service, or zero if
a test is not required.