Dialogic DSI SPCI Network Interface Boards User Manual
Page 103
Dialogic
®
DSI SPCI Network Interface Boards Programmer's Manual Issue 5
103
This must not exceed the maximum number of circuit groups supported
otherwise module configuration will fail. Typically
to the maximum number of circuit groups supported.
not exceed the maximum number of circuits supported otherwise module
configuration will fail. Typically
groups for E1 operation and 24 times the number of circuit groups for T1
operation.
Note: The valid range for the circuit identifier (cid) is from zero up to one less than the
maximum number of circuits (num_ccts).
This parameter is the module_id of the ‘partner’ ISUP module (equivalent to
the ‘module_id field in the ISUP Configure Request message as documented
in the ISUP Programmer’s Manual).
7.3.2
ISUP Circuit Group Configuration
Syntax:
ISUP_CFG_CCTGRP
Example: ISUP_CFG_CCTGRP
0
3
1 1 0x7fff7fff 0x00000003 0 0x2d
2 0x8 4 0x00000000
The configuration parameters for a group of ISUP circuits. Usually a group is
all the circuits on a single E1 or T1 interface.
of groups supported.
circuit group.
to one less than the number of circuits supported.