beautypg.com

6 mtp2 level 2 state indication – Dialogic DSI SPCI Network Interface Boards User Manual

Page 86

background image

6 Message Reference

86

6.4.6

MTP2 Level 2 State Indication

Synopsis:
Indication issued by the board every time the level 2 link state control state
machine changes state.

Message Format:

MESSAGE HEADER

Field Name

Meaning

type MGT_MSG_SS7_STATE (0x0201)

id llid (Level 2 logical link id - 0 ... 3)

src SS7_TASK_ID

dst 0xdf

rsp_req

0

hclass

0

status Link

State (see below)

err_info

Reserved for future use

len

0

Description:
This message is issued by the MTP2 module every time a change of state
takes place at level 2. It is intended only for diagnostic use by system

management. Normally the MTP Pause and MTP Resume Indications are used

by the user parts to determine destination accessibility.

The level 2 link state control state machine is defined in Q.703.

Parameter Description:

Link State
The status field in the message header is used to indicate the state that has

just been entered. It is coded as follows:

Value

Mnemonic

State

1

S7S_IN_SERVICE

In Service

2

S7S_OUT_SERVICE

Out of Service

3

S7S_INIT_ALIGN

Initial Alignment

4

S7S_ALIGN_NOT_RDY

Aligned, Not Ready

5

S7S_ALIGN_READY

Aligned, Ready

6

S7S_PROC_OUTAGE

Processor Outage