8 height, Off status on – TeeJet CenterLine User Guide v2.02 User Manual
Page 17

CenterLine 2.02
98-05054 R6
13
Antenna - Height
The Height setting defines the height of the GPS antenna to the ground surface. This value is used
only when a tilt sensor is connected. To change the height setting, navigate to
the Arrow buttons until
Arrow buttons to select
height value until the desired distance is displayed in the text window. Press the Enter button to save
the setting and return to the Guidance setup menu.
Figure 2-17: Establishing Antenna Height
Status
If a Swath Manager 5 is connected to the system, the Status option will be removed from the main
setup. Status setup is used to auto detect implement status. When the status detect is properly
implemented, CenterLine will detect whether product delivery is ON or OFF based on the vehicle
product ON/OFF switch. Refer to Figures 2-1 and 2-2 for the location of status connect (boom
sense) wiring.
To adjust Status, navigate to
press the Enter button. Options are either ON or OFF. Use the Arrow buttons to choose the appropri-
ate option and press the Enter button to save the settings and return to the Guidance setup menu.
Figure 2-18: Status Selection
Table 2-4: Status Settings
Alarm
The Alarm setting, when enabled, notifies the operator when entering a previously applied area. The
text window will display
field. To adjust the alarm setting, navigate to
is displayed and press the Enter button. Options are either ON or OFF. Use the Arrow buttons to
choose the appropriate option and press the Enter button to save the settings and return to the Guid-
ance setup menu.
Setting
Description
Off
No status detect is implemented. This is the default setting.
On
Status detect assumes a single swath centered on the vehicle.
9.8
Height
Off
Status
On
NOTE:
When
is set to ON, +12V
must be supplied
to the boom sense
wire when booms
are ON. If this
does not occur,
applied area
detection will not
work. Refer to the
CenterLine wiring
tips document 98-
01095.
Arrow buttons