~ Appendix C: Control Panel

88

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Appendix C: Control Panel

This equipment must be

installed according to

applicable local

electrical codes.

!

1 2 3 4 5 6 7 8

O N

O N

Figure C.1. DIP switches

Figure C.2. DIP switch settings

Figure C.3. Wiring the Control Panels

The Volume Control Panel and Select Control Panel connect to either the Remote

Panel A or B connector of the PSR1212, XAP 800, or XAP 400 and works by

triggering the execution of programmed commands from the XAP/PSR unit. Each

button on the control panel is programmable to execute a single command or a

series of commands. Button function is programmed using G-Ware software (see

the XAP or PSR user manual). Each Control Panel fits inside a standard electrical

wall box and must be installed according to local electrical codes.

Connecting the Control Panel

1.

Ensure you received a facia plate; a Control Panel assembly with mounting

bracket and two RS-485 Phoenix four-pin connectors; two connector

terminator blocks; a faceplate; two flat HD screws; two pan-head screws;

and an electrical wall box (shown in Figures C.5 and C.6). If any parts are

missing, please contact ClearOne.

2.

Using DIP switches 1–4, assign a unique ID to the Control Panel. Refer to

Figure C.2 for proper DIP switch settings. If you set an invalid address, all LEDs

on the Control Panel will illuminate.

3.

Set DIP switch 8 to the on position if you are using just one Control Panel. If you

have more than one Control Panel daisy-chained to the same Remote Panel

connector, set

only the last Control Panel’s DIP switch 8 to on. Switches 5-7 are

nonfunctional.

4.

Turn off the XAP/PSR unit (unplug the unit).

5.

Wire each end of a Cat. 5 cable to a connector terminator block. Use one

twisted wire pair for the center - and + connections (pins 2 and 3) and the

other twisted pair for the ground and +15V connections (pins 1 and 4).

Failure to correctly wire the connector can result in damage to the unit.