beautypg.com

Lfp - lock front panel, Lmo - last mic on mode, Lock - preset and macro lock – ClearOne comm PSR1212 User Manual

Page 114: Argument details, Appendices ~ appendix e: serial commands

background image

108

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

LFP - Lock Front Panel

This command sets and reports front panel access for the unit. When the unit is

locked, access is not allowed to the unit until the unit is unlocked.

Command form: DEVICE

LFP [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

LFP

Command form

Value

0 = Unlock Panel, 1 = Lock Panel, 2 = Toggle Value,

3 = Lock when timed out

Example:

#44 LFP 1 The PSR1212 unit 4 (#44), front panel (LFP) is locked (1).

LMO - Last Mic On Mode

This command selects/reports last Mic on mode for the specified gating group.

Command form: DEVICE

LMO [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

LMO

Command form

Channel

See Groups and Channels, page 93

Value

0 = Last Mic Mode disabled

1–8 = Select Last Mic mode on specified channel

* = Last mic to stay on, Null to return the current mode

Example:

#40 LMO A 0 On PSR1212 unit 0 (#40), the Last Mic Mode (LMO)

for gating group

A is disabled (0).

LOCK - Preset and Macro Lock

This command selects/reports the state of the preset and macro lock. When on, the

lock prevents flagged presets and macros from being altered in any way.

Command form: DEVICE

LOCK [Value][Password]

Argument details

Name

Description

Device

0–7 or * to select all units

LOCK

Command form

Value

0 = Off, 1 = On, 2 = Toggle

Password

Needs to be entered only when changing the lock. For security,

this value is not returned.

Example:

#41 LOCK 1 “password” On PSR1212 unit 1 (#41), any presets or

macros that have been flagged with the LOCKPRST command will be locked (

LOCK)

and password protected (

1) with the macro/preset password (LOCKPWD).

Appendices

~ Appendix E: Serial Commands