Command

Function

NOM

Selects/reports NOM setting on output

channels

OFFA

Selects/reports off attenuation mode for

Inputs 1–8

PAA

Selects PA adapt mode for specified input

PP

Selects/reports phantom power setting

PRESET

Executes preset or reports last executed preset

PRGSTRING

Sets/reports a programmed string

RAMP

Start/stops the gain ramp for an input, output,

or assignable processing block

REFSEL

Selects/reports PA adapt mode for mic outputs

REFSET

Selects/reports the output the reference channel

tracks

Command

Function

SERECHO

Selects/reports the serial echo of the RS-232

SERMODE

Selects/reports the serial mode of the RS-232

SFTYMUTE

Selects/reports the state of the safety mute.

When on, the safety mute holds all outputs in a

muted state.

SIGGEN

Selects/reports signal generator activation

SIGTOUT

Sets the signal generator time out for the unit

STRING

Executes a string for the RS-232 port

TOUT

Selects/reports the title screen inactivity time

out

UID

Reports unit ID (read only)

VER

Reports unit version (read only)