MUTE - Mute
This command selects/reports the setting of mute on input, output or processing
channels.
Command form: DEVICE
MUTE
Argument details
Name
Description
Device
0–7 or * to select all units
MUTE
Command form
Channel
See Groups and Channels, page 93
Group
I, O, M, P, L
Value
0 = Off, 1 = On, 2 = Toggle, Null = current mode
Example:
#41 MUTE 2 M 1 On PSR1212 unit 1 (#41), the mute (MUTE) for
mic (
M) channel 2 is on (1).
NOM - Number of Open Microphones Mode
This command selects/reports the setting of Number of Open Microphones (NOM) on
output channels. Command form: DEVICE
NOM
Argument details
Name
Description
Device
0–7 or * to select all units
NOM
Command form
Channel
1–12 (select output)
Value
0 = Off, 1 = On, 2 = Toggle, Null = Current mode
Example:
#45 NOM 2 1 On PSR1212 unit 5 (#45), the number of open
microphones (
NOM) attenuation for output 2 is on (1).
OFFA - Off Attenuation Mode
This command selects/reports the off attenuation mode of input channels 1–8.
Command form: DEVICE
OFFA
Argument details
Name
Description
Units
Device
0–7 or * to select all units
OFFA
Command
Channel
1–8 (select mic input)
Value
0–60 (select off attenuation level)
dB
Null to return the current off attenuation level
Example:
#46 OFFA 1 12 On PSR1212 unit 6 (#46), the off attenuation
(
OFFA) for mic channel 1 is 12dB.