FILTSEL - Filter Select
This command turns on and off the filters on input and audio processing channels.
Command form: DEVICE
FILTSEL
Argument details
Name
Description
Device
0–7 or * to select all units
FILTSEL
Command form
Channel
See Groups and Channels, page 93
Group
M = Mic Inputs, P = Processing Channels
Node
1-4, or * for all (selects mic input filter)
1-15, or * for all (selects processing channel filter)
Value
0 = Off, 1 = On, 2 = Toggle, Null to return current state
Example:
#44 FILTSEL B P 2 1 On PSR1212 unit 4 (#44), the filter
(
FILTSEL) on processing (P) channel B, node 2, is set to on (1).
FLOW - Flow Control
This command selects/reports the flow control of the serial port on the unit.
Hardware flow control is implemented using DTR and DSR.
Command form:
DEVICE
FLOW [Value]
Argument details
Name
Description
Device
0–7 or * to select all units
FLOW
Command form
Value
0 = Off, 1 = On, 2 = Toggle, Null to return current state
Example:
#46 FLOW 1 On PSR1212 unit 6 (#46), the flow control (FLOW) to
the RS-232 port is set to on (
1).
FMP - First Mic Priority Mode
This command selects/reports first Mic priority mode for a gating group.
Command form: DEVICE
FMP
Argument details
Name
Description
Device
0–7 or * to select all units
FMP
Command form
Channel
1–4, A–D (selects gating group)
Value
0 = Off, 1 = On, 2 = Toggle, Null returns the current mode
Example:
#45 FMP A 1 On PSR1212 unit 5 (#45), the first mic priority mode
(
FMP) for gating group A is set to on (1).