Appendices

~ Appendix E: Serial Commands

GREPORT - Gate Report

This command selects/reports the gate status.

Command form: DEVICE

GREPORT

Argument details

Name

Description

Device

0–7 or * to select all units

GREPORT

Command form

Value

0 = Off, 1 = On, 2 = Toggle

Example:

#43 GREPORT 1 On PSR1212 unit 3 (#43), the gate reporting

(

GREPORT) is set to on (1).

GRPSEL - Gating Group Select

This command selects/reports which gating group each input is assigned. There can

be only one selection per input.

Command form: DEVICE

GRPSEL [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

GRPSEL

Command form

Channel

1–8 (selects mic input)

Value

1–4, A–D (selects gating group), Null to return current value

Example:

#44 GRPSEL 1 A On PSR1212 unit 4 (#44), mic channel 1 is

assigned to gating group (

GRPSEL) A.

LABEL - Label

This selects/reports the label of the specific channel identified in the unit.

Command form: DEVICE

LABEL [In/Out] [String]

Argument details

Name

Description

Device

0–7 or * to select all units

LABEL

Command form

Channel

See Groups and Channels, page 93

Group

I, O, M, G, P, L, E, U, W, S, C (see page 93)

In/Out

0 = Output, 1 = Input (For expansion bus groups only)

String

String of up to 20 characters representing the label text.

Null to query and CLEAR to clear the label

Example:

#47 LABEL 1 M WIRELESS On PSR1212 unit 7 (#47), the label

(

LABEL) for mic (M) channel 1 is WIRELESS.

Gate report sends a

report on every gate

change. If no mics are

gated on, the report will be sent

every 10 seconds.

-