MACRO - Macro Execution/Reporting

This command executes a specified macro or reports the last macro executed. There

are 255 macros that can be specified.

Command form: DEVICE

MACRO [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

MACRO

Command form

Value

1-255

Value to execute user macros

Example:

#45 MACRO 1 On PSR1212 unit 5 (#45), Macro (MACRO) 1 is

run.

MASTER - Expansion Bus Master Mode

This command reports the mode of the unit. The mode can be Master or Slave.

Command form: DEVICE

MASTER [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

MASTER

Command form

Value

1 = Master, 2 = Slave, Null = Current mode of the unit

Example:

#46 MASTER 2 On PSR1212 unit 6 (#46), the MASTER mode is

set to slave (

2).

MAX - Maximum Gain Setting

This command changes or reports back the maximum gain setting for an input,

output or assignable processing block.

Command form: DEVICE

MAX [Value]

Argument details

Name

Description

Units

Device

0–7 or * to select all units

MAX

Command form

Channel

See Groups and Channels, page 93

Group

I, O, M, P, L

Value

-65.00 to 20.00

dB

Null to return the current setting

Example:

#41 MAX 2 M 10 On PSR1212 unit 1 (#41), the maximum (MAX)

relative gain setting for mic (

M) channel 2 is 10dB.

The response indicates

execution of the macro,

but does not indicate

that each command within the

macro was executed.

-

This setting will affect

all relative gain

adjustments.

-