Macro - macro execution/reporting, Master - expansion bus master mode, Max - maximum gain setting – ClearOne comm PSR1212 User Manual
Page 117

111
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Appendices
~ Appendix E: Serial Commands
MACRO - Macro Execution/Reporting
This command executes a specified macro or reports the last macro executed. There
are 255 macros that can be specified.
Command form: DEVICE
MACRO [Value]
Argument details
Name
Description
Device
0–7 or * to select all units
MACRO
Command form
Value
1-255
Value to execute user macros
Example:
#45 MACRO 1 On PSR1212 unit 5 (#45), Macro (MACRO) 1 is
run.
MASTER - Expansion Bus Master Mode
This command reports the mode of the unit. The mode can be Master or Slave.
Command form: DEVICE
MASTER [Value]
Argument details
Name
Description
Device
0–7 or * to select all units
MASTER
Command form
Value
1 = Master, 2 = Slave, Null = Current mode of the unit
Example:
#46 MASTER 2 On PSR1212 unit 6 (#46), the MASTER mode is
set to slave (
2).
MAX - Maximum Gain Setting
This command changes or reports back the maximum gain setting for an input,
output or assignable processing block.
Command form: DEVICE
MAX
Argument details
Name
Description
Units
Device
0–7 or * to select all units
MAX
Command form
Channel
See Groups and Channels, page 93
Group
I, O, M, P, L
Value
-65.00 to 20.00
dB
Null to return the current setting
Example:
#41 MAX 2 M 10 On PSR1212 unit 1 (#41), the maximum (MAX)
relative gain setting for mic (
M) channel 2 is 10dB.
The response indicates
execution of the macro,
but does not indicate
that each command within the
macro was executed.
-
This setting will affect
all relative gain
adjustments.
-