beautypg.com

System configuration ~ inputs and outputs – ClearOne comm PSR1212 User Manual

Page 43

background image

37

System Configuration

~ Inputs and Outputs

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Ambient Level if you want to specify a fixed reference point rather than one that

adjusts for background noise. The range is from -80 to 0dB. Default is Off.

Decay Rate

Decay Rate determines how fast a channel gates off after the hold time expires.

Default is Medium.

PA Adapt and AEC Reference

When using the PA Adaptive mode, the output that carries this information, i.e. the

reference output, must be defined. Select the reference output from the PA Adapt

and AEC Reference list. Any one of the 12 outputs, four expansion bus references, or

four virtual references can be selected.

If you select an

expansion bus reference, the Define PA Adapt/AEC

Expansion Bus Ref window opens so you can identify which expansion bus output you

want to use as the PA reference. You can also open this window from the toolbar.

Figure 3.29. PSR1212 automixing gate functions

Figure 3.30. PA Adapt/AEC

window and toolbar button