Sigtout - signal generator time out, String - string execution, Tout - time out select – ClearOne comm PSR1212 User Manual
Page 128

122
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Appendices
~ Appendix E: Serial Commands
SIGTOUT - Signal Generator Time Out
Sets the signal generator time out for the unit.
Command form: DEVICE
SIGTOUT [Value]
Argument details
Name
Description
Device
0–7 or * to select all units
SIGGEN
Command
Value
0 = Off, 1–30 = Set time out minutes, Null = Current rate
Example:
#47 SIGTOUT 15 On PSR1212 unit 7 (#47), the signal generator
time out (
SIGTOUT) is set to 15 minutes.
STRING - String Execution
This command sends the specified string out the serial port.
Command form: DEVICE
STRING [ID]
Argument details
Name
Description
Device
0–7 or * to select all units
STRING
Command
ID
0 – 7
Null to query last string in text
Example:
#41 STRING 3 On PSR1212 unit 1 (#41), the STRING programmed
into location
3 will be sent out the RS-232 port.
TOUT - Time Out Select
This command selects/reports the inactivity time out before returning to the unit title
screen.
Command form: DEVICE
TOUT [Value]
Argument details
Name
Description
Device
0–7 or * to select all units
TOUT
Command
Value
0 = Off, 1–15 (select time out in minutes)
Null = Current mode
Example:
#42 TOUT 5 On PSR1212 unit 2 (#42), the front panel of the unit
will time out (
TOUT) after 5 minutes.
The serial command to
create a string is
PRGSTRING (Program
String). See page 118.
-