Refset - reference channel setup, Serecho - serial echo, Sermode - serial mode – ClearOne comm PSR1212 User Manual
Page 126

120
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
REFSET - Reference channel setup
This command selects/reports the output the reference channel tracks.
Command form: DEVICE
REFSET
Argument details
Name
Description
Device
0–7 or * to select all units
REFSET
Command
Channel
1–4 (select Virtual Reference number)
Group
1–9 (select output channel to track)
Value
0 = none
Example:
#43 REFSET 2 4 On PSR1212 unit 3 (#43), virtual reference (2) will
track gain changes made on output channel 4.
SERECHO - Serial Echo
This command selects/reports the serial echo of the RS-232 port.
Command form: DEVICE
SERECHO [Value]
Argument details
Name
Description
Device
0–7 or * to select all units
SERECHO
Command
Channel
See Groups and Channels, page 93
Value
0 = Off, 1 = On, 2 = Toggle, Null = Current state
Example:
#44 SERECHO 1 On PSR1212 unit 4 (#44), the serial echo
(
SERECHO) of the RS-232 port is set to on (1).
SERMODE - Serial Mode
This command selects/reports the serial mode of the RS-232 port.
Command form: DEVICE
SERMODE [Value]
Argument details
Name
Description
Device
0–7 or * to select all units
SERMODE
Command
Value
1 = Text, 2 = Binary, Null = Current mode
Example:
#45 SERMODE 1 On PSR1212 unit 5 (#45), the RS-232 port serial
mode (
SERMODE) is set to text (1).
Appendices
~ Appendix E: Serial Commands
If the serial mode is
changed, the terminal
will not see a response
from the unit, nor will the unit
respond to commands until the
new status is matched by the
terminal.
-