Dfltm - default meter, Did - device id, Argument details – ClearOne comm PSR1212 User Manual
Page 107: Appendices ~ appendix e: serial commands

101
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
DFLTM - Default Meter
This command selects/reports the setting of the default meter.
Command form: DEVICE
DFLTM [Channel] [Group] [Position]
Argument details
Name
Description
Device
0–7 or * to select all units
DFLTM
Command form
Channel
1–12
Group
I = Inputs, O = Outputs, M = Mic Inputs, L= Line Inputs
Position
I, A, N, G, as applicable for group
(see Meter Type definitions, page 94)
Example:
#45 DFLTM 8 O A On PSR1212 unit 5 (#45), the default meter
(
DFLTM) is set to output (O) 8 after the gain adjustment (A).
DID - Device ID
This command selects/reports the device ID.
Command form:
DEVICE
DID [Value]
Argument details
Name
Description
Device
0–7 or * to select all units
DID
Command form
Value
0–7 (select device ID)
Example:
#47 DID 0 On PSR1212 unit 7 (#47), the device ID (DID) is set to 0.
Appendices
~ Appendix E: Serial Commands