beautypg.com

Compaq AA-RHGWC-TE User Manual

Page 188

background image

wwid2

wwid3
N1

50001fe100000d64

N2

50001fe100000d62

N3

50001fe100000d63

N4

50001fe100000d61

P00>>> init

h.

Set the bootdef_dev console environment variable to the member
system boot device. Use the paths shown in the reachability display
of the wwidmgr -quickset command for the appropriate device
(see Section 6.6.6).

i.

Repeat steps a through h on each system accessing devices on the
HSG80.

6.8 Using the emx Manager to Display Fibre Channel

Adapter Information

The emx manager (emxmgr) utility was written for the TruCluster Software
Product Version 1.6 products to be used to modify and maintain emx driver
worldwide name to target ID mappings. It is included with Tru64 UNIX
Version 5.1 and, although not needed to maintain worldwide name to target
ID mappings, it may be used with TruCluster Server Version 5.1 to:

Display the presence of KGPSA Fibre Channel adapters

Display the target ID mappings for a Fibre Channel adapter

Display the current Fibre Channel topology for a Fibre Channel adapter

See emxmgr

(8)

for more information on the emxmgr utility.

6.8.1 Using the emxmgr Utility to Display Fibre Channel Adapter

Information

The primary use of the emxmgr utility for TruCluster Server is to display
Fibre Channel information.

Use the emxmgr -d command to display the presence of KGPSA Fibre
Channel adapters on the system. For example:

# /usr/sbin/emxmgr -d

emx0 emx1 emx2

Use the emxmgr -m command to display an adapter’s target ID mapping.
For example:

# /usr/sbin/emxmgr -m emx0

emx0 SCSI target id assignments:

SCSI tgt id

0 : portname 5000-1FE1-0000-0CB2

6–62 Using Fibre Channel Storage