6.6.1.2 Adding Units and Identifiers to the HSG80 Storagesets

After you have created the storagesets (mirrorsets and partitions), assign
a unit number to each partition and set a unique identifier as shown in
Example 6–3. The steps performed in Example 6–3 include:

Assign a unit number to each storage unit and disable all access to the
storage unit.

Set an identifier for each storage unit.

Enable selective access to the storage unit.

Example 6–3: Adding Units and Identifiers to the HSG80 Storagesets

HSG80> ADD UNIT D131 BOOT-MIR PARTITION=1 DISABLE_ACCESS_PATH=ALL

1

HSG80> ADD UNIT D132 BOOT-MIR PARTITION=2 DISABLE_ACCESS_PATH=ALL

HSG80> ADD UNIT D133 BOOT-MIR PARTITION=3 DISABLE_ACCESS_PATH=ALL

HSG80> ADD UNIT D141 CROOT-MIR PARTITION=1 DISABLE_ACCESS_PATH=ALL

HSG80> ADD UNIT D142 CROOT-MIR PARTITION=2 DISABLE_ACCESS_PATH=ALL

HSG80> ADD UNIT D143 CROOT-MIR PARTITION=3 DISABLE_ACCESS_PATH=ALL

HSG80> ADD UNIT D144 CROOT-MIR PARTITION=4 DISABLE_ACCESS_PATH=ALL

HSG80> SET D131 IDENTIFIER=131

2

HSG80> SET D132 IDENTIFIER=132

HSG80> SET D133 IDENTIFIER=133

HSG80> SET D141 IDENTIFIER=141

HSG80> SET D142 IDENTIFIER=142

HSG80> SET D143 IDENTIFIER=143

HSG80> SET D144 IDENTIFIER=144

HSG80> set d131 ENABLE_ACCESS_PATH = !NEWCON49,!NEWCON50,!NEWCON51,!NEWCON52

3

HSG80> set d131 ENABLE_ACCESS_PATH = !NEWCON53,!NEWCON54,!NEWCON55,!NEWCON56

Warning 1000: Other host(s) in addition to the one(s) specified can still

access this unit.

If you wish to enable ONLY the host(s)

specified, disable all access paths (DISABLE_ACCESS=ALL), then

again enable the ones specified

HSG80> set d131 ENABLE_ACCESS_PATH = !NEWCON61,!NEWCON62,!NEWCON64,!NEWCON65

Warning 1000: Other host(s) in addition to the one(s) specified can still

access this unit.

If you wish to enable ONLY the host(s)

specified, disable all access paths (DISABLE_ACCESS=ALL), then

again enable the ones specified

HSG80> set d131 ENABLE_ACCESS_PATH = !NEWCON68,!NEWCON74,!NEWCON76,!NEWCON77

Warning 1000: Other host(s) in addition to the one(s) specified can still

access this unit.

If you wish to enable ONLY the host(s)

specified, disable all access paths (DISABLE_ACCESS=ALL), then

again enable the ones specified

HSG80> set d132 ENABLE_ACCESS_PATH = !NEWCON49,!NEWCON50,!NEWCON51,!NEWCON52
.

.

.

HSG80> set d144 ENABLE_ACCESS_PATH = !NEWCON49,!NEWCON50,!NEWCON51,!NEWCON52

HSG80> set d144 ENABLE_ACCESS_PATH = !NEWCON53,!NEWCON54,!NEWCON55,!NEWCON56

Warning 1000: Other host(s) in addition to the one(s) specified can still

access this unit.

If you wish to enable ONLY the host(s)

specified, disable all access paths (DISABLE_ACCESS=ALL), then

again enable the ones specified

HSG80> set d144 ENABLE_ACCESS_PATH = !NEWCON61,!NEWCON62,!NEWCON64,!NEWCON65
Warning 1000: Other host(s) in addition to the one(s) specified can still

access this unit.

If you wish to enable ONLY the host(s)

specified, disable all access paths (DISABLE_ACCESS=ALL), then

6–40 Using Fibre Channel Storage