beautypg.com

17 technical data – ALTANA Wave-Scan II User Manual

Page 53

background image

52

English

General technical data:

Temperature range

10°C to 40°C (operation)

0°C to 60°C (storage)

Rel. humidity

up to 85% at 35°C, non-condensing

Measurement unit:

Battery power supply

3 x 1.5V DC; 0.5A
Alkaline batteries AA / LR6

Rechargeable battery

Measurement operation: 3.6 VDC; 1.0A; 1950 mAh

pack

Charging operation: 4.2 VDC; 1.0 A

Battery capacity

approx. 1000 readings

Application
wave-scan dual

High to Semi Gloss (du < 65, linear range)

wave-scan II

High Gloss Surfaces (du < 40, linear range)

Structure spectrum

du:

< 0.1 mm

Wa

0.1 to 0.3 mm

Wb

0.3 to 1.0 mm

Wc

1.0 to 3.0 mm

Wd

3.0 to 10.0 mm

We

10.0 to 30.0 mm

Scanlength

5, 10 and 20 cm

Repeatability

du < 40: 4% or > 0.4 (standard deviation)
du > 40: 6% or > 0.6 (standard deviation)

Reproducibility

du < 40: 6% or > 0.6 (standard deviation)
du > 40: 8% or > 0.8 (standard deviation)

Object radius

> 500 mm

Smallest sample size

35 mm x 150 mm

Resolution

375 points / cm

Memory

1500 measurements

Interface

USB 1.1

Light source

Laser diode LED and IR-SLD

Laser energy

< 1 mW (laser class 2)

Dimensions (WxLxH)

55 x 150 x 110 mm

Weight

650 g

17

Technical data

This manual is related to the following products: