17 technical data – ALTANA Wave-Scan II User Manual
Page 53

52
English
General technical data:
Temperature range
10°C to 40°C (operation)
0°C to 60°C (storage)
Rel. humidity
up to 85% at 35°C, non-condensing
Measurement unit:
Battery power supply
3 x 1.5V DC; 0.5A
Alkaline batteries AA / LR6
Rechargeable battery
Measurement operation: 3.6 VDC; 1.0A; 1950 mAh
pack
Charging operation: 4.2 VDC; 1.0 A
Battery capacity
approx. 1000 readings
Application
wave-scan dual
High to Semi Gloss (du < 65, linear range)
wave-scan II
High Gloss Surfaces (du < 40, linear range)
Structure spectrum
du:
< 0.1 mm
Wa
0.1 to 0.3 mm
Wb
0.3 to 1.0 mm
Wc
1.0 to 3.0 mm
Wd
3.0 to 10.0 mm
We
10.0 to 30.0 mm
Scanlength
5, 10 and 20 cm
Repeatability
du < 40: 4% or > 0.4 (standard deviation)
du > 40: 6% or > 0.6 (standard deviation)
Reproducibility
du < 40: 6% or > 0.6 (standard deviation)
du > 40: 8% or > 0.8 (standard deviation)
Object radius
> 500 mm
Smallest sample size
35 mm x 150 mm
Resolution
375 points / cm
Memory
1500 measurements
Interface
USB 1.1
Light source
Laser diode LED and IR-SLD
Laser energy
< 1 mW (laser class 2)
Dimensions (WxLxH)
55 x 150 x 110 mm
Weight
650 g
17