Figure 3-2: Recommended Minimum Clearances for Servicing (AM750 / AM1000)

NOTE

Service clearances are minimum required clearances for ease of
access, but larger service clearances are always preferred.

3.6 Clearances to Combustible Material

This unit may be installed directly onto a floor of combustible material with the following
clearances:

Table 3-1: Unit Installation Clearance Dimensions

Component

Clearance Distance

Ceiling

2 inches (51 mm)

Front

2 inches (51 mm)

Rear

2 inches (51 mm)

Sides

2 inches (51 mm)

Floor

0 inches (0 mm)

Concentric vent

0 inches (0 mm)

Split vent (two pipes) first 3 feet from the boiler

1 inch (25 mm)

Split vent (two pipes) after 3 feet from the boiler

0 inches (0 mm)

Boiler piping

¼ inch (7 mm)