34

Buttons

Use this to enable or disable the following front panel keys:

Select - Choose Yes or No to enable or disable the SELECT

key.

Units - Choose Yes or No to enable or disable the UNITS

key.

Reset - Choose Yes or No to enable or disable the PEAK

RESET key.

Send - You have two items to configure in this submenu.

PB Send - Use this to determine which layouts are sent

to which ports for pushbutton data send. You

can choose a Group number to send a

preconfigured layout, disable the pushbutton

data send, or save the information to the

database rather than outputting to the serial

port. If you choose the Save option and the

database is full, the display will show Full

when you press the DATA SEND key.

n Send -

Use this to enable or disable the ability to key

in a group number then press the DATA

SEND key to send that group data to a serial

port.

Zero - Choose Yes or No to enable or disable the ZERO key.

Menu - Choose Yes or No to enable or disable the MENU key.

F1 -

Choose Yes or No to enable or disable the F1 key.

F2 -

Choose Yes or No to enable or disable the F2 key.

F3 -

Choose Yes or No to enable or disable the F3 key.

Display

The Display submenu allows you to customize the order in
which the FI-127 cycles through its weight display modes and
units of measure.

Select

Customize the list of weight display modes here. The default list
is: ForceÆTopÆPeak. Repeatedly pressing SELECT while in
the Display mode will cycle through the list in that order. You
may customize the list by inserting and/or deleting items in the
list. The list can contain a maximum of four items.

To add an item: Determine where in the list you wish to insert
an item. Display the item which will immediately follow the one
you are inserting. Press +/-. The ACCEPT annunciator illumi-
nates. Cycle through the options by pressing the Е

Е

Е

Е

Е or MENU

keys until the item you wish to insert is displayed, then press
ENTER. That item is now included in the list.

To delete an item: With that item displayed, press ZERO. That
item is deleted from the list.

Units

Customize the list of units of measure here. The default list is:
Unit 1ÆUnit 2ÆUnit 3. Repeatedly pressing UNITS while
displaying a weight in the weight display mode will cycle through
the list in that order. You may customize the list by inserting
and/or deleting items in the list. The list can contain a maximum
of four items.