1 script apply, 2 script apply nointerl.scr, At8901m management commands – Kontron AT8901M CLI User Manual
Page 283

AT8901M
Management Commands
Page 6 - 31
AT8901M CLI Reference Manual
You should use scripts on systems with default configuration; however, you are not
prevented from applying scripts on systems with non-default configurations.
Scripts must conform to the following rules:
•
The file extension must be “.scr”.
•
A maximum of ten scripts are allowed on the switch.
•
The combined size of all script files on the switch shall not exceed 2048 KB.
•
The maximum number of configuration file command lines is 2000.
You can type single-line annotations at the command prompt to use when you write test
or configuration scripts to improve script readability. The exclamation point (!)
character flags the beginning of a comment. The comment flag character can begin a
word anywhere on the command line, and all input following this character is ignored.
Any command line that begins with the “!” character is recognized as a comment line
and ignored by the parser.
The following lines show an example of a script:
! Script file for displaying management access
show telnet !Displays the information about remote connections
! Display information about direct connections
show serial
! End of the script file!
NOTE: To specify a blank password for a user in the configuration script, you
must specify it as a space within quotes. For example, to change the
password for user
jane
from a blank password to
hello
, the script
entry is as follows:
users passwd jane
" "
hello
hello
6.10.1
script apply
This command applies the commands in the script to the switch. The
parameter is the name of the script to apply.
Format
script apply
Mode
Privileged EXEC
6.10.2
script apply nointerl.scr
This command disables the connections between redundant hub boards. When two hub
boards are inserted into a standard ATCA chassis, they are connected via direct GE
connections on channel 2 for the base fabric.
These connections may create bridging loops when enabled. During normal operation,
it is often useful to completely separate the redundant hub boards and thus create up to
four independent switching/bridging domains.
The boards come with a script installed that disables the interlinks. This script can be
applied to disable the respective interfaces, i.e.
•
interface 0/19 for the base fabric