AVer EH6216H+ user manual User Manual
Page 131
123
CHAPTER 4
-
Start Recording
Record the video from the selected camera.
Beside the Start Recording check box, click Detail.
1. In the Alarm Recording Setting dialog box, select
the camera to enable/disable video recording.
Enable All to select all cameras.
2. In the Frame Rate selection, select As Setting to
record the number of frames based on the
Recording Setting.
3. In the Start Record prior text box, mark and set
the number in second for the program to begin
recording after the alarm has been trigger. The
time range is 1~10 seconds.
4. In the Stop Record after text box, mark and set
the number in second for the program to continue recording after the alarm has ended. The time
range is 1~999 seconds. If user doesn
’t mark and set the time, the alarm recording will continue
recording until alarm is reset.
5. Click OK to accept the new settings and Cancel to exit without saving.
i
EH6108H
+
only supports 8 channels.
- PTZ preset point
Position the PTZ camera based on the preset point setting.
Beside the PTZ preset point check box, click Detail. In the
Trigger PTZ Preset Setting dialog box, select the PTZ
camera number then select the Enable check box. Select
the position of the PTZ camera when the alarm is activated
and ended. For the PTZ camera end point, user can also
select on preset position or Auto Pan between preset
position groups.