Cooper Instruments & Systems DFI INFINITY B Ultra High Performance Digital Force Indicator User Manual
Page 81

resolution; 0.1% accuracy; 6 msec step response.
RELAY OUTPUT, OPTIONAL:
Form -C, SPDT Relays
POWER
RATING
FOR
RESISTIVE LOADS:
Two relays at P6 and P7
30Vdc or 250 Vac @ 5 Amp
Two relays at P18A and P18B
30 Vdc or 250 Vac @ 3 Amp
(see Figure 5-9)
TURNDOWN RATIO
(MAX OFFSET-MIN SPAN):
1000 with 0.1% or 100 with 0.01% resolution
NETWORK AND COMMUNICATIONS,OPTIONAL:
ETHERNET:
Standards Compliance IEEE 802.3 10Base-T
SUPPORTED
PROTOCOLS: TCP/IP, ARP, HTTPGET, TELNET
RS-232 / RS-422 / RS-485 /
MODBUS:
Selectable from menu; both ASCII and modbus protocol
selectable from menu. Programmable 300 to 19.2 K baud;
complete programmable setup capability; program to transmit
current display, alarm status, min/max, actual measure input
value and status.
RS-485
(HALF AND FULL DUPLEX):
Addressable from 0 to 199
ISOLATION
See CE Approvals Section
POWER
LINE
VOLTAGE/POWER
VOLTAGES:
90-240 Vac, +/-10%
FREQUENCY:
50/60
Hz
POWER:
8.5 watts, max
EXTERNAL
FUSE
PROTECTION REQUIRED:
IEC127-2/III, 250 mA (Time-Lag) or UL Slow-Blow
LOW
VOLTAGE/POWER
OPTION
VOLTAGES:
10-32
Vdc
POWER:
8 watts, max
External power source must meet Safety Agency Approvals.
ENVIRONMENTAL
OPERATING TEMP RANGE:
0 to 50 ºC (32 to 140°F)
STORAGE TEMP RANGE:
-40 to 85 ºC (-40 to 202°F)
HUMIDITY:
up to 95% non-condensing at 40°C (104°F)
FRONT
PANEL:
NEMA-4
rated
MECHANICAL
DIMENSIONS (H x W x D):
1.89 x 3.78 x 5.86in. (48 x 96 x 145mm)
PANEL CUTOUT (H x W):
1/8 DIN 1.772 X 3.622in. (45 x 92mm)
WEIGHT:
1.2 pounds (448 g)
MATERIAL:
94V-0
UL-rated
Polycarbonate
APPROVALS
See CE Approvals Section.
CF 156
76
M2544/N/0505