beautypg.com

1 ana.out – Cooper Instruments & Systems DFI INFINITY B Ultra High Performance Digital Force Indicator User Manual

Page 56

background image


OUt.CNF

Enter OUTPUT CONFIGURATION MENU:

Press ‘MENU

1) 5 times or scroll though main Menu until Display shows "OUt.CNF" Output
Configuration Menu.

20.1 ANA.OUt

Press ‘RESET/ENTER

2) Display shows "ANA.OUt" Analog Output Configuration submenu.

Press ‘RESET/ENTER

3) Display flashes "dISAbL" (Default) or previous setting option.

Press ‘▲/MAX

4) Select "ENAbLE" to setup Analog Output if your controller is equipped with the
optional Analog Output board.


MOdE

Enter OUTPUT MODE CONFIGURATION SUBMENU:

Press ‘RESET/ENTER

5) Display shows "StOREd" stored message momentarily and advances to "MOdE" to
allow users to select Output type as Voltage (0-10Vdc or Current (4-20mA-dc) source.

Press ‘RESET/ENTER

6) Display flashes "VOLt" (default) DC-Voltage output option or previous selection
("CURRNt" DC-Current output).

OUt.tyP

Enter OUTPUT TYPE CONFIGURATION SUBMENU:

Press ‘RESET/ENTER

7) Display shows "OUt.tyP" Output Type Submenu.

Press ‘RESET/ENTER

8) Display flashes "UNF ILt" Unfiltered option or previous selection.

Press ‘▲/MAX

9) Scroll though and select the following options for your choice of setting:

"UNF ILt" :Transmits the unfiltered value of your signal input.
"FILtRd" : Transmits the filtered value of your signal input.
"PEAk" : Transmits the recorded Peak "HI RdG" Reading value(s).
or
"VALLy" : Transmits the recorded Valley "LO RdG" Reading value(s).

CF 156

51

M2544/N/0505