1 ana.out – Cooper Instruments & Systems DFI INFINITY B Ultra High Performance Digital Force Indicator User Manual
Page 56

OUt.CNF
Enter OUTPUT CONFIGURATION MENU:
Press ‘MENU’
1) 5 times or scroll though main Menu until Display shows "OUt.CNF" Output
Configuration Menu.
20.1 ANA.OUt
Press ‘RESET/ENTER’
2) Display shows "ANA.OUt" Analog Output Configuration submenu.
Press ‘RESET/ENTER’
3) Display flashes "dISAbL" (Default) or previous setting option.
Press ‘▲/MAX’
4) Select "ENAbLE" to setup Analog Output if your controller is equipped with the
optional Analog Output board.
MOdE
Enter OUTPUT MODE CONFIGURATION SUBMENU:
Press ‘RESET/ENTER’
5) Display shows "StOREd" stored message momentarily and advances to "MOdE" to
allow users to select Output type as Voltage (0-10Vdc or Current (4-20mA-dc) source.
Press ‘RESET/ENTER’
6) Display flashes "VOLt" (default) DC-Voltage output option or previous selection
("CURRNt" DC-Current output).
OUt.tyP
Enter OUTPUT TYPE CONFIGURATION SUBMENU:
Press ‘RESET/ENTER’
7) Display shows "OUt.tyP" Output Type Submenu.
Press ‘RESET/ENTER’
8) Display flashes "UNF ILt" Unfiltered option or previous selection.
Press ‘▲/MAX’
9) Scroll though and select the following options for your choice of setting:
"UNF ILt" :Transmits the unfiltered value of your signal input.
"FILtRd" : Transmits the filtered value of your signal input.
"PEAk" : Transmits the recorded Peak "HI RdG" Reading value(s).
or
"VALLy" : Transmits the recorded Valley "LO RdG" Reading value(s).
CF 156
51