Cooper Instruments & Systems DFI INFINITY B Ultra High Performance Digital Force Indicator User Manual
Cooper Instruments & Systems Measuring instruments
Table of contents
Document Outline
- NOTES, WARNINGS AND CAUTIONS
- 1.0 INTRODUCTION
- 2.0 UNPACKING
- 3.0 SAFETY CONSIDERATIONS
- 4.0 PARTS OF THE METER
- 5.0 SETUP
- 6.0 JUMPER SETTINGS
- 6.1 THERMOCOUPLE Input:
- 6.2 RTD Input:
- 6.3 VOLTAGE/PROCESS VALUE Input:
- 6.4 CURRENT/PROCESS VALUE Input:
- 6.5 BRIDGE Input:
- 6.5.1 For ± 50mV, 0-100mV ranges with Internal Excitation:
- 6.5.2 For ±50mV, 0-100mV ranges with External Excitation:
- 6.5.3 For ± 500mV, 1V ranges with Internal Excitation:
- 6.5.4 For ± 500mV, 1V ranges with External Excitation:
- 6.5.5 For ± 5V, 0-10V ranges with Internal Excitation:
- 6.5.6 For ± 5V, 0-10V ranges with External Excitation:
- 6.5.7 For ± 50V, 0-100V ranges with Internal Excitation:
- 6.5.8 For ± 50V, 0-100V ranges with External Excitation:
- 6.5.9 For 0-20mA or 4-20mA range with Internal Excitation:
- 6.5.10 For 0-20mA or 4-20mA range with External Excitation:
- 6.5.11 POTENTIOMETER Input:
- 7.0 SIGNAL AND POWER INPUT CONNECTIONS
- 8.0 SETPOINT SETTINGS MENU FLOWCHART
- 9.0 ACTIVE BUTTONS: ‘SETPTS’, ‘▲/MAX’, ‘►/MIN’.
- 10.0 MAIN MENU CONFIGURATION FLOWCHART
- 11.0 INPUT TYPE MENU FLOWCHART: (INPUT)
- 12.0 INPUT TYPE SELECTION: (INPUT)
- 13.0 READING CONFIGURATION MENU AND FLOWCHART: (RDG.CNF)
- 14.0 READING CONFIGURATION MENU:
- 14.1 RD.SC.OF Enter READING SCALE & OFFSET Submenu:
- 14.2 UNt.tMP Enter TEMPERATURE UNIT SELECTION Submenu:
- 14.3 dEC Pt Enter DECIMAL POINT CONFIGURATION Submenu:
- 14.4 FILtER Enter FILTER CONFIGURATION Submenu:
- 14.5 FLS.dSP Enter FLASHING DISPLAY CONTROL Submenu:
- 14.6 bRIGHt Enter DISPLAY BRIGHTNESS CONTROL Submenu:
- 15.0 INPUT CONFIGURATION FLOWCHART
- 16.0 INPUT CONFIGURATION MENU: (INP.CNF)
- 17.0 MULTI-POINT SCALE & OFFSET MENU CONFIGURATION FLOWCHART
- 18.0 MULTI-POINT SCALE & OFFSET MENU CONFIGURATION: (MP.SC.OF)
- 19.0 OUTPUT CONFIGURATION MENU FLOWCHART
- 20.0 OUTPUT CONFIGURATION MENU: (OUT.CNF)
- 21.0 SETPOINT CONFIGURATION MENU FLOWCHART
- 22.0 SETPOINT CONFIGURATION MENU: (SP.CNF)
- 23.0 ALARM CONFIGURATION MENU FLOWCHART
- 24.0 ALARM CONFIGURATION MENU: (AL.CNFG)
- 25.0 COMMUNICATION CONFIGURATION FLOWCHART
- 26.0 COMMUNICATION MENU CONFIGURATION: (COMM)
- 27.0 DISPLAY COLOR SELECTION MENU FLOWCHART:
- 28.0 DISPLAY COLOR SELECTION MENU: (COLOR)
- 29.0 LOCKOUT (ACCESS SECURITY) CONFIGURATION MENU FLOWCHART:
- 30.0 LOCKOUT (ACCESS SECURITY) CONFIGURATION MENU
- 31.0 EXTERNAL CONTROL LINES
- 31.1 TARE (PIN 1)
- 31.2 PEAK (PIN 2)
- 31.3 VALLEY (PIN 3)
- 31.4 SWLIN2 (PIN 4)
- 31.5 EXTERNAL RESET (PIN 5)
- 31.6 NO CONNECTION (PIN 6)
- 31.7 DIGITAL RETURN (PIN 7)
- 31.8 +5 V (PIN 8)
- 31.9 DISPLAY HOLD (PIN 9)
- 31.10 LOCKOUT EEPROM (AND ‘MENU’ BUTTON) (PIN 10)
- 31.11 RESET OF ALARMS (PIN 11)
- 31.12 NONSTANDARD RX (PIN 12) AND NONSTANDARD TX (PIN 13)
- 31.13 NO CONNECTION (PIN 14)
- 31.14 +V EXT (PIN 15)
- 31.15 SP1 (PIN 16)
- 31.16 SP2 (PIN 17)
- 31.17 AL1 (PIN 18)
- 31.18 AL2 (PIN 19)
- 31.19 RTN EXT (PIN 20)
- 32.0 TROUBLESHOOTING - DISPLAY MESSAGES AND TROUBLESHOOTING GUIDE
- 32.1 Error Mode Messages
- 32.1.1 Flashing “999999” (Numerical Overflow)
- 32.1.2 Flashing “ERR 01” (Offset Overflow)
- 32.1.3 Flashing “ERR 02” (Setpoint Overflow)
- 32.1.4 “NOSTOR” and “STORED” (Programming Entries In EEPROM)
- 32.1.5 Flashing “OVLD” (Positive Input Overload)
- 32.1.6 Flashing “OPEN” (Open Sensor Indication)
- 32.1.7 Flashing “-OPEN” (Open Sensor Indication)
- 32.1.8 Flashing “I OVSC” (Input Overscale)
- 32.1.9 Flashing “R OVSC” (Reading Overscale)
- 32.1.10 Flashing “CB OVF” (Count By Overflow)
- 32.1.11 Flashing “UOM.OVF” (Unit Of Measure Overflow)
- 32.1.12 Flashing “dP OVF” (Decimal Point Overflow)
- 32.2 Troubleshooting Guide
- 33.1 Current Input
- 33.2 Voltage Input
- 33.3 Potentiometer Input
- 33.4 Thermocouple Input
- 33.5 RTD Input
- 33.5 RTD Input continued
- 33.6 General
- 33.7 Flashing Messages:
- 33.8 ITS-90 Thermocouple Tables
- 33.9 RTD 10 ohm Copper Table
- 3.10 ITS-90 RTD 385 Table
- 33.11 ITS-90 RTD 392 US Table
- 32.1 Error Mode Messages
- 34.0 FACTORY PRESET VALUES
- 35.0 RECORD YOUR SETUP VALUES
- CE APPROVALS INFORMATION
- WARRANTY REPAIR POLICY