beautypg.com

2 unt.tmp enter temperature unit selection submenu, 3 dec pt enter decimal point configuration submenu – Cooper Instruments & Systems DFI INFINITY B Ultra High Performance Digital Force Indicator User Manual

Page 43

background image

Press ‘RESET/ENTER

22) Display shows "xxxxxx" some 6-digit number, represents the value of "INPUt 1" as
taken from live input source measurement for desired value.

Press ‘RESET/ENTER

23) Display shows "REAd 1" Item #2 of coordinate #1.

Press ‘RESET/ENTER

24) Display shows "xxxxxx" some 6-digit number with first digit flashing, represents the
value of "REAd 1" item #2 of coordinate #1.

Press ‘▲/MAX’ & ‘►/MIN’ 25) Use ‘MAX’ and ‘MIN’ buttons to enter new value of "REAd 1".
Press ‘RESET/ENTER

26) Display shows "INPUt 2" Item #1 of coordinate #2. Continue to proceed with the
selection and value entry, for "INPUt 1" and "REAd 1" for "INPUt 2" and "REAd 2", (item
#1 and #2 of coordinate #2), similar to steps above.

Press ‘RESET/ENTER

27) Display advances to "UNt.tMP" Temperature Unit selection Submenu. If an item # of
coordinate # was prompted or modified, the controller will also show the "StOREd" stored
message momentarily.

MANUAL

Press ‘RESET/ENTER’ 28)

"MANUAL" heading stops flashing.

Press ‘RESET/ENTER

29) Display shows "INPUt 1" Item #1 of coordinate #1.
Pressing ‘RESET/ENTER’ to sequence through:

"INPUt 1", Input 1 ‘s value
"REAd 1", Read 1 ‘s value
"INPUt 2", Input 2 ‘s value
"REAd 2", Read 2 ‘s value

headings for the desired selection and continue using ‘MAX’ and ‘MIN’ buttons to manually
enter or modify the values as described in the following section.

Press ‘RESET/ENTER

30) Display shows "xxxxxx" some 6-digit number with first digit flashing, represents the
value of "INPUt" item #1 of coordinate #1.

Press ‘▲/MAX’ & ‘►/MIN’ 31) Use ‘MAX’ and ‘MIN’ buttons to enter new value of "INPUt 1" item #1 of coordinate #1.
Press ‘RESET/ENTER

32) Display shows "REAd 1". Continue the sequential items with ‘MAX’ & ‘MIN’ buttons to
select and enter values.

Press ‘RESET/ENTER

33) Display advances to "UNt.tMP" Temperature Unit selection Submenu. If an item # of
coordinate # was prompted or modified, the controller will also show the "StOREd" stored
message momentarily.

14.2 UNt.tMP

Enter TEMPERATURE UNIT SELECTION Submenu:

1) To enter TEMPERATURE UNIT SELECTION Submenu if display shows "UNt.tMP"
(Second Item of "RdG.CNF" Menu).

Press ‘RESET/ENTER

2) Display shows flashing "C" (default) and front display shows °C accordingly at the
bottom right side or previous temperature Unit selection.

Press ‘▲/MAX

3) Scroll through the 3 supported selections to the Temperature Unit of your choice: "C",
"F" and "k" (°C, °F and °K units).

Press ‘RESET/ENTER

4) Display advances to "dEC Pt" Decimal Point Setting Menu. If a change was made,
the controller will also show the "StOREd" stored message momentarily.

14.3 dEC Pt

Enter DECIMAL POINT CONFIGURATION Submenu:

CF 156