141
Thru Port Input
Impedance, Nominal
VSWR (Max.)
Max RF Input
Bias Tee (on Thru port)
DC Voltage, Nominal
Current Supply
Current Measurement
Activity
Immunity
Test Port
Thru Port
50 ohms
1.5:1
+22 dBm
AISG TMA DC Supply Class 1 and Class 2
12V or 24V, user-selectable
0-800 mA, 1A surge, 12V
0-400 mA, 0.5A surge, 24V
±5%
+13 dBm
+13 dBc or +13 dBm Max interferer, whichever is less
Measurements
Overview
Analyzes VSWR and Return Loss (dB) of single-
port devices. Measures antenna and cable
performance. Provides immunity to interference.
Allows setup of parameters such as frequency,
amplitude, and markers. Graphically displays
amplitude vs. frequency and saves traces.
Predefined Measurements
Return Loss, VSWR, Match, Cable Loss,
Distance to Fault, Insertion Loss, Gain, DC Bias
Current Draw
DTF Cable List
Includes Vp and loss/freq parameters for 100+ cable
types, user may update cable list as needed.
Markers
6 Markers; Modes: On/Off, Standard, Marker to
Max Peak, Marker to Next Peak, Marker to Min
Valley, Marker to Next Valley, Marker Delta,
Marker Display, Marker Type Line/Icon, All Marker
to Max Peaks, All Markers to Min Valleys, All
Markers Off, Marker to Max/Min Peak via Up/
Down Arrow Keys, Marker Left/Right via Left/Right
Arrow Keys, and Wheel.