beautypg.com

Rockwell Automation GV3000/SE AC Drive 1-20HP, 230VAC Ver. 6.04 Hdwe Ref, Install, Troubleshooting User Manual

Page 48

background image

5-6

GV3000/SE 230 VAC 1-20 HP Drive, Hardware Reference Version 6.04

ATTENTION: Do not route signal and control wiring in the same
conduit with power wiring. This can cause interference with drive
operation. Failure to observe this precaution could result in damage
to, or destruction of, the equipment.

ATTENTION: If the GV3000/SE drive is connected to an external DC
bus, the user is responsible for DC bus short-circuit protection. Failure
to observe this precaution could result in damage to, or destruction of,
the equipment.

Step 2. Connect the DC input power leads (two-wire 310 VDC nominal) to

terminals + and – on the power terminal strip.

Note that the maximum discharge rate of the DC bus supply should be
100 V/second.

Step 3. Tighten the DC input power terminals to 1.2-1.4 Newton-meters (10-12

lb-in) for 1-5 HP drives, 2.0-2.4 Newton-meters (17-20 lb-in) for 7.5 and 10
HP drives, and 2.5-2.9 Newton-meters (22-26 lb-in) for 15 and 20 HP
drives.

!