3-6

GV3000/SE 230 VAC 1-20 HP Drive, Hardware Reference Version 6.04

GV3000/SE

Drive

GV3000/SE

Drive

GV3000/SE

Drive

GV3000/SE

Drive

Motor

Motor

Motor

Motor

Motor

Motor

Motor

38 m (125')

38 m (125')

15 m (50')

61 m (200')

8 m (25')

61 m (200')

8 m (25')

76 m (250')

All examples represent 76 m (250') of motor lead length.

Figure 3.3 – How to Measure Motor Lead Lengths

Table 3.7 - Motor Lead Lengths

GV3000/SE

HP Rating

Maximum Lead Length in Feet with

230 VAC Motor

Carrier Frequency

Filter Type

2 kHz

4 kHZ

8 kHZ

1 to 2
3 to 5

7.5 to 10

15 to 20

1 to 2
3 to 5

7.5 to 10

15 to 20

500
500
750
800

1000
1000
1000
1000

500
500
500
500

1000
1000
1000
1000

500
500
500
500

1000
1000
1000
1000

None

A 5% MTE

reactor/filter at the

drive.

Note that the lead lengths listed are valid with Reliance Electric inverter duty motors.

Table 3.8 - Reactors

GV3000/SE

HP Rating

GV3000/SE

HP Rating

240 Volt

5% MTE Reactor

240 Volt

5% MTE Reactor

1
2
3
5

7.5

10
15
20

RL-00402
RL-00802
RL-01202
RL-01802

RL-02502
RL-03502
RL-04502
RL-05502

These part numbers are for a reactor with a capacitor filter.
MTE standard reactors can be used on GV3000/SE drives with carrier frequency settings up to 8 kHZ.
All reactors listed are UL-recognized (UL-506 File #E53094) and CSA certified (CSA File #LR29753).