Parameter Descriptions
4-41
Sets the time that the drive will remain in power loss mode before a fault is issued.
Sets the level at which the Power Loss Mode selection will occur.
Selects the source for control of drive direction.
Unipolar = Drive receives unsigned reference (0 to 32767) and direction command
separately (from the DPI port). For example, the direction keys on an OIM apply the
direction to the reference.
Bipolar = Drive receives signed reference (-32767 to 32767). In this case, the
direction keys have no effect.
Reverse Disable = Drive receives signed reference (-32767 to 32767); however,
regardless of the reference, the drive is not permitted to reverse.
185
Power Loss Time
Range:
0.0 to 60.0 sec [0.1 sec]
Default:
0.5 sec
Access:
0
Path: Dynamic Control>Power Loss
See also:
184
186
Power Loss Level
Range:
0.0 to 99.9 [0.1 VDC]
Default:
Drive Rated Volts
Access:
1
Path: Dynamic Control>Power Loss
See also:
184
190
Direction Mode
Range:
0 = Unipolar
1 = Bipolar
2 = Reverse Dis
Default:
2 = Reverse Dis
Access:
0
Path: Utility>Direction Config
See also:
320 - 327, 361 - 366
!
ATTENTION: Setting parameter 190 to 0 or 1 may cause unwanted motor
direction. Verify driven machinery cannot be damaged by reverse rotation
before changing the setting of this parameter to 0 or 1. Failure to observe
this precaution could result in damage to, or destruction of, equipment.