4-40
LiquiFlo 1.5 AC Drive, Software Reference Version 1.2
Defines the amount of time at or above Wake Level before a start command is issued.
This parameter is not used with LiquiFlo AC drives.
Defines the analog input level that will stop the drive. This parameter is not used with
LiquiFlo AC drives.
Defines the amount of time at or below Sleep Level before a stop command is issued.
This parameter is not used with LiquiFlo AC drives.
Sets the reaction to a loss of input power. Power loss is recognized when:
DC bus voltage is
≤
73% of DC Bus Memory and Power Loss Mode is set to Coast.
DC bus voltage is
≤
82% of DC Bus Memory and Power Loss Mode is set to Decel.
181
Wake Time
Range:
0.0 to 30.0 [0.1 sec]
Default:
1.0
Access:
1
Path: Dynamic Control>Restart Modes
See also:
180
182
Sleep Level
Range:
4.000 mA, 0.000 V / Wake Level [0.001 mA, 0.001 V]
Default:
5.000 mA, 5.000 V
Access:
1
Path: Dynamic Control>Restart Modes
See also:
183
183
Sleep Time
Range:
0.0 to 30.0 [0.1 sec]
Default:
1.0
Access:
1
Path: Dynamic Control>Restart Modes
See also:
182
184
Power Loss Mode
Range:
0 = Coast
1 = Decel
2 = Continue
3 = Coast input
4 = Decel input
Default:
0 = Coast
Access:
0
Path: Dynamic Control>Power Loss
See also:
184