Rockwell Automation 2755-DM9, -DM9E High Speed Decoder User Manual
Page 70
Chapter 4
Configuring Your Decoder
4–43
10) Press the [RETURN] key to enter the No-Read message and then press
the [ESC] key to select the command bar. Notice that the five commands are
shown on the bottom of the display:
------- MESSAGE FORMAT ------- ------- HOST COMM -------
SEND BAR CODE DATA:
Yes
BAUD RATE:
9600
SEND PACKAGE COUNT:
No
BITS/CHAR:
8 Data, 1 Stop
SEND BAR CODE TYPE:
No
PARITY:
None
SEND SOURCE IDENTIFIER:
No
SEND HEADER MESSAGE:
No
ACK CHAR:
None
SEND NO-READ MESSAGE:
Yes
NAK CHAR:
None
START SCAN CHAR:
None
EXPAND UPC-E:
Yes
STOP SCAN CHAR:
None
SOURCE IDENTIFIER:
LARGE BUFFER:
No
LABEL DELIMITER:
None
RESPONSE MODE:
Valid Package
START CHAR:
None
HOST PROTOCOL:
RS232
END MESSAGE:
CRLF
DEVICE ADDRESS:
01
TRANSMISSION CHECK:
None
HEADER MESSAGE:
NO-READ MESSAGE:
NO-READ
CODE 39 CHECK CHAR:
No SEND: No ---PACKAGE DETECT INPUT---
I 2-OF-5 CHECK CHAR:
No SEND: No FILTER: No
CODABAR CHECK CHAR:
No SEND: No SENSE: LO = Package
COMMAND --
Exit: ESC Select: RETURN Next Command: SPACE
NEXT PAGE THIS PAGE RECALL SAVE DEFAULT
11) Notice that the NEXT PAGE command is highlighted. Press the
[RETURN] key to enter the command. The next setup screen will be
displayed:
-- SYMBOLOGY -- -------- LENGTHS -------- -------- SCANNER CONTROL --------
CODE 39: Yes
00 00 00 00 00 00 00 00
LASER-ON MODE:
Continuous
I 2-OF-5: No
00 00 00 00 00 00 00 00 DECODE TRIGGER:
Package Detect
CODE 128: No
00 00 00 00 00 00 00 00
CAPTURE COUNT:
2 (scans)
CODABAR: No
00 00 00 00 00 00 00 00
FIELDS/SCAN:
1
UPC-A: No
FIELDS/PACKAGE:
1
UPC-E: No
NO-READ TIMER:
0000 (msec)
EAN-8: No
INTER-SCAN TIMER:
0000 (msec)
EAN-13: No
MATCH COMPLETE:
1
------------MATCH CODE TABLE-------------- --------- OUTPUTS [DISABLED]---------
1) CODE 39 N
None
0000
2) CODE 39 N
None
0000
3) CODE 39 N
None
0000
4) CODE 39 N
None
0000
5) CODE 39 N
None
0000
6) CODE 39 N
None
0000
7) CODE 39 N
None
0000
8) CODE 39 N
None
0000
Commands: ESC Change: SPACE Cursor Control: ARROWS