Reference
Letter
Description
Field
Type
Options (Select Field
Only)
Valid Entries (Edit Field
Only)
j
Specified code lengths for Interleaved
2–of–5. Includes check character.
Edit
N/A
Even numeric
entries from
0 through 64. 0 indicates
no length check. Must be
even number.
k
Specified code lengths for Code 128.
Does not include start, stop, or check
characters.
Edit
N/A
Numeric entries from 0
through 64. 0 indicates no
length check.
l
Specified code lengths for Codabar.
Includes start, stop, and check
characters.
Edit
N/A
Numeric entries from 0
through 64. 0 indicates no
length check.
m
Laser–On mode select.
Select
Continuous or
Triggered.
N/A
n
Trigger select.
Select
Package Detect, Host
Command, Internal
Timer, Continuous.
N/A
o
Capture count.
Edit
N/A
Numeric value from 1
through 8.
p
Number of bar code fields per scan.
Select
1, 2, 3, 4 or Any
N/A
q
Number of bar code fields per package.
Edit
N/A
Numeric value from 1
through 8.
r
No–read timer (milliseconds).
Edit
N/A
Numeric value from 10
through 9999. 0 indicates
no timer.
s
Inter–scan timer (milliseconds).
Edit
N/A
Numeric value from 10
through 9999. 0 indicates
no timer.
t
Match complete count.
Edit
N/A
Numeric value from 1
through 8.
u
Bar code symbology for match code
operation.
Select
Code 39,
Interleaved 2–of–5,
Code 128,
Codabar,
UPC–A,
UPC–E,
EAN–8,
EAN–13
N/A
v
Enable for match code operation.
Select
Y or N