Interface
Chapter 7
Host Commands Using the RS-232 or RS-422
7–18
Note: Host port communication parameters are not changed to default values
with this command.
Response:
=98
Comments:
The response of
=98
indicates that the command has been
received and the decoder is resetting.
Note: The decoder enters the factory set parameters, saves the configuration
in the EEPROM, and resets. Operation will then resume according to the
default configuration parameters. Refer to Appendix B for factory set
parameters. The reset operation takes approximately 5 seconds.
Command:
RN
Function:
Saves decoder configuration to memory and restarts decoder.
Response:
=97
Comments:
The response of
=97
indicates that the command has been
received and the decoder is resetting.
Note: The decoder saves the new configuration in the EEPROM and resets.
Operation will then resume according to the new configuration parameters.
The reset operation takes approximately 5 seconds.
Command:
SA
Function:
Saves decoder configuration to memory.
Response:
=00
Comments:
The response of
=00
indicates that the command has been
received.
Note: The decoder saves the new configuration in the EEPROM. Operation
will then continue according to the new configuration parameters.