Communication Connections 4-15
1761-CBL-PM02 Series C (or equivalent) Cable Wiring Diagram
Recommended User-supplied Components
These components can be purchased from your local electronics supplier.
Cable
Length
Connections from
to AIC+ External
Power Supply
Required
(1)
Power
Selection
Switch
Setting
(1)
1761-CBL-AS03
1761-CBL-AS09
3m (9.8 ft)
9.5m (31.17 ft)
SLC 500 Fixed,
SLC 5/01, SLC 5/02, and SLC 5/03
processors
port 3
yes
external
PanelView 550 RJ45 port
port 3
yes
external
(1) External power supply required unless the AIC+ is powered by the device connected to port 2, then the selection switch should be set to cable.
Table 4.7 User Supplied Components
Component
Recommended Model
external power supply and chassis ground
power supply rated for 20.4 to 28.8V dc
NULL modem adapter
standard AT
straight 9-25 pin RS-232 cable
see table below for port information if
making own cables
Programming
Device
Controller
9-Pin D-Shell
8-Pin Mini Din
9
RI
24V
1
8
CTS
GND
2
7
RTS
RTS
3
6
DSR
RXD
4
5
GND
DCD
5
4
DTR
CTS
6
3
TXD
TXD
7
2
RXD
GND
8
1
DCD