Parameter cross reference––by number – Rockwell Automation 1336T ControlNet Frn1.02 Rev 1.5 User Manual
Page 215

9–5
Specifications and Supplemental Information
Publication 1336 FORCE–5.18 ––March, 1999
The following table lists the parameters in numerical order.
No.
Name
Group➀
Page
No.
Name
Group➀
Page
300
Adapter ID
1 –– Adapter Info
6–12
344
Data Out A2
3 –– SCANport I/O
6–19
301
Adapter Version
1 –– Adapter Info
6–12
345
Data Out B1
3 –– SCANport I/O
6–19
302
SP Comm Retries
1 –– Adapter Info
6–12
346
Data Out B2
3 –– SCANport I/O
6–19
303
ChA DIP Switch
7 –– Channel A
6–12
347
Data Out C1
3 –– SCANport I/O
6–19
304
348
Data Out C2
3 –– SCANport I/O
6–19
305
ChA LED State
7 –– Channel A
6–12
349
Data Out D1
3 –– SCANport I/O
6–20
306
350
Data Out D2
3 –– SCANport I/O
6–20
307
ICN Board Status
1 –– Adapter Info
6–13
351
CntlNet Out 0
7 –– Channel A
6–20
309
Language Sel
1 –– Adapter Info
6–13
352
CntlNet Out 1
7 –– Channel A
6–20
314
Data In A1
3 –– SCANport I/O
6–13
353
CntlNet Out 2
7 –– Channel A
6–21
315
Data In A2
3 –– SCANport I/O
6–13
354
CntlNet Out 3
7 –– Channel A
6–21
316
Data In B1
3 –– SCANport I/O
6–13
355
CntlNet Out 4
7 –– Channel A
6–21
317
Data In B2
3 –– SCANport I/O
6–13
356
CntlNet Out 5
7 –– Channel A
6–22
318
Data In C1
3 –– SCANport I/O
6–14
357
CntlNet Out 6
7 –– Channel A
6–22
319
Data In C2
3 –– SCANport I/O
6–14
358
CntlNet Out 7
7 –– Channel A
6–22
320
Data In D1
3 –– SCANport I/O
6–14
359
321
Data In D2
3 –– SCANport I/O
6–14
360
322
CntlNet In 0
7 –– Channel A
6–15
361
323
CntlNet In 1
7 –– Channel A
6–15
362
324
CntlNet In 2
7 –– Channel A
6–15
363
325
CntlNet In 3
7 –– Channel A
6–16
364
326
CntlNet In 4
7 –– Channel A
6–16
365
327
CntlNet In 5
7 –– Channel A
6–16
366
328
CntlNet In 6
7 –– Channel A
6–17
367
CntlNet Cmd In
3 –– Logic
6–23
329
CntlNet In 7
7 –– Channel A
6–17
368
330
369
Stop Owner
5 –– Owners
6–23
331
370
Dir Owner
5 –– Owners
6–23
332
371
Start Owner
5 –– Owners
6–24
333
372
Jog 1 Owner
5 –– Owners
6–24
334
373
Jog 2 Owner
5 –– Owners
6–24
335
374
Set Ref Owner
5 –– Owners
6–24
336
375
Local Owner
5 –– Owners
6–24
337
376
Flux Owner
5 –– Owners
6–25
338
SP Analog In
3 –– Analog Input
6–17
377
Trim Owner
5 –– Owners
6–25
339
Analog In 1
6 –– Analog Input
6–18
378
Ramp Owner
5 –– Owners
6–25
340
Analog In 2
6 –– Analog Input
6–18
379
Clr Fault Owner
5 –– Owners
6–25
341
Analog In 3
6 –– Analog Input
6–18
386
SP Analog Out
3 –– Analog Output
6–25
342
Analog In 4
6 –– Analog Input
6–18
387
Analog Out 1
6 –– Analog Output
6–26
343
Data Out A1
3 –– SCANport I/O
6–19
388
Analog Out 2
6 –– Analog Output
6–26
➀ Parameters included in Groups 7 and 8 depend on the selected
communications.
Shaded parameters do not exist when DH+ is selected. Inputs are
variable and depend on rack size and whether block transfer is
enabled.
Parameter Cross
Reference––By Number
"