6–20
Parameters
Publication 1336 FORCE–5.18 ––March, 1999
349
Data Output D1
[Data Out D1]
Data Out D1 contains the seventh image word from
the SCANport input image table.
Parameter Number
349
Parameter Type
Read/Write, Sink
Display Units / Drive Units
None
Factory Default
0
Minimum Value
0 Hex
Maximum Value
FFFF Hex
File – Group
Communications I/O – SCANport I/O
350
Data Output D2
[Data Out D2]
Data Out D2 contains the eighth image word from
the SCANport input image table.
Parameter Number
350
Parameter Type
Read/Write, Sink
Display Units / Drive Units
None
Factory Default
0
Minimum Value
0 Hex
Maximum Value
FFFF Hex
File – Group
Communications I/O – SCANport I/O
351
CntlNet Out 0
[CntlNet Out 0]
CntlNet Out 0 contains the first word or data group
to the PLC controller input image table. The data is
transferred to the PLC controller every rack scan.
The ControlNet Adapter Board can provide this
value directly. Other drive functions can provide this
value through a configuration link.
Parameter Number
351
Parameter Type
Read/Write, Sink
Display Units / Drive Units
None
Factory Default
None
Minimum Value
–32767
Maximum Value
+32767
File – Group
Communications I/O – Channel A
352
CntlNet Out 1
[CntlNet Out 1]
CntlNet Out 1 contains the second word or data
group to the PLC controller input image table. The
data is transferred to the PLC controller every rack
scan. The ControlNet Adapter Board can provide
this value directly. Other drive functions can provide
this value through a configuration link.
Parameter Number
352
Parameter Type
Read/Write, Sink
Display Units / Drive Units
None
Factory Default
None
Minimum Value
–32767
Maximum Value
+32767
File – Group
Communications I/O – Channel A