Rockwell Automation 1336T ControlNet Frn1.02 Rev 1.5 User Manual
Page 173
![background image](/manuals/578189/173/background.png)
6–31
Parameters
Publication 1336 FORCE–5.18 ––March, 1999
408
Port Enable
[Port Enable]
Port Enable indicates which ports can accept
commands listed in parameters 409 through 415.
Parameter Number
408
Parameter Type
Read/Write, Non–Linkable Sink
Display Units / Drive Units
Bits
Factory Default
0
Minimum Value
0
Maximum Value
0FE Hex
File – Group
Communications I/O – SCANport Masks
Enums
Bit 1 = Port 1
Bit 2 = Port 2
Bit 3 = Port 3
Bit 4 = Port 4
Bit 5 = Port 5
Bit 6 = Channel A Bit 7 = Channel B
409
Direction Mask
[Dir Mask]
Dir Mask controls which ports can issue
forward/reverse commands.
Parameter Number
409
Parameter Type
Read/Write, Non–Linkable Sink
Display Units / Drive Units
Bits
Factory Default
0
Minimum Value
0
Maximum Value
0FE Hex
File – Group
Communications I/O – SCANport Masks
Enums
Bit 1 = Port 1
Bit 2 = Port 2
Bit 3 = Port 3
Bit 4 = Port 4
Bit 5 = Port 5
Bit 6 = Channel A Bit 7 = Channel B
410
Start Mask
[Start Mask]
Start Mask controls which ports can issue a start
command.
Parameter Number
410
Parameter Type
Read/Write, Non–Linkable Sink
Display Units / Drive Units
Bits
Factory Default
0
Minimum Value
0
Maximum Value
0FE Hex
File – Group
Communications I/O – SCANport Masks
Enums
Bit 1 = Port 1
Bit 2 = Port 2
Bit 3 = Port 3
Bit 4 = Port 4
Bit 5 = Port 5
Bit 6 = Channel A Bit 7 = Channel B
411
Jog Mask
[Jog Mask]
Jog Mask controls which ports can issue a jog
command.
Parameter Number
411
Parameter Type
Read/Write, Non–Linkable Sink
Display Units / Drive Units
Bits
Factory Default
0
Minimum Value
0
Maximum Value
0FE Hex
File – Group
Communications I/O – SCANport Masks
Enums
Bit 1 = Port 1
Bit 2 = Port 2
Bit 3 = Port 3
Bit 4 = Port 4
Bit 5 = Port 5
Bit 6 = Channel A Bit 7 = Channel B
412
Reference Mask
[Ref Mask]
Ref Mask controls which ports can select an
alternate reference or preset speed.
Parameter Number
412
Parameter Type
Read/Write, Non–Linkable Sink
Display Units / Drive Units
Bits
Factory Default
0
Minimum Value
0
Maximum Value
0FE Hex
File – Group
Communication I/O – SCANport Masks
Enums
Bit 1 = Port 1
Bit 2 = Port 2
Bit 3 = Port 3
Bit 4 = Port 4
Bit 5 = Port 5
Bit 6 = Channel A Bit 7 = Channel B