Rockwell Automation 1336T ControlNet Frn1.02 Rev 1.5 User Manual
Page 178
![background image](/manuals/578189/178/background.png)
6–36
Parameters
Publication 1336 FORCE–5.18 ––March, 1999
443
SCANport Warning Status
[SP Warn Sts]
SP Warn Sts indicates which communications
warnings the drive has encountered at the ports.
Parameter Number
443
Parameter Type
Read Only, Source
Display Units / Drive Units
Bits
Factory Default
0011
1110
Minimum Value
0000
0000
Maximum Value
0011
1110
File – Group
Diagnostics – Fault Select/Status
Communications I/O – Fault Select/Status
Enums
Bit 7 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1
Enums
Warning
Port 1
SP Pt1 Timeout (Flt 26038)
Port 2
SP Pt2 Timeout (Flt 26039)
Port 3
SP Pt3 Timeout (Flt 26040)
Port 4
SP Pt4 Timeout (Flt 26041)
Port 5
SP Pt5 Timeout (Flt 26042)
SP Offline
454
Trend Input 1
[Trend In 1]
Trend In 1 specifies the data value to sample at the
specified trend sample rate. You should link Trend
In 1 to a source parameter (such as velocity, torque,
or current) for the trend to make sense.
Parameter Number
454
Parameter Type
Read/Write, Sink
Display Units / Drive Units
Dependent on Link➀
Factory Default
0
Minimum Value
–32767➀
Maximum Value
+32767➀
File – Group
Diagnostics – Trend I/O
➀ These values depend on the source parameter that this parameter is linked to.
For example, if the source parameter’s drive units are rpm, then Trend In 1’s drive
units will be displayed in rpm. The minimum and maximum values are also link
dependent.
455
Trend 1 Operand Parameter X
[Tr1 Opnd Parm X]
Tr1 Opnd Parm X specifies the first of two parameter
numbers for the trend trigger evaluation. The data
value for the entered link parameter number is used
in the trigger evaluation.
Parameter Number
455
Parameter Type
Read/Write, Sink
Display Units / Drive Units
Dependent on Link➀
Factory Default
0
Minimum Value
–32767➀
Maximum Value
+32767➀
File – Group
Diagnostics – Trend Setup
➀ These values depend on the source parameter that this parameter is linked to.
For example, if the source parameter’s drive units are rpm, then Tr1 Opnd Parm X’s
drive units will be displayed in rpm. The minimum and maximum values are also
link dependent.