beautypg.com

Rockwell Automation 150 SMC-Flex User Manual User Manual

Page 97

background image

Programming

4-13

All braking/stopping current settings in the range of 1…100% will provide 100% braking current
to the motor.

Option

Parameter

Range

Slow Speed

with Braking

SMC Option

This parameter identifies the type of
control present and is not user
programmable.

Braking Control

Slow Speed Select

Allows the user to program the slow
speed that best fits the application.

Low:7%
High:15%

Slow Accel Current

Allows the user to program the
required current to accelerate the
motor to slow speed operation.

0…450% of full load
current

Slow Running Current

Allows the user to program the
required current to operate the
motor at the slow speed setting.

0…450% of full load
current

Braking Current

Allows the user to program the
intensity of the braking current
applied to the motor.

0…400% of full load
current