Specifications

A-5

Environmental

The product’s allowable operational ambient temperature must be derated by -3 °C (-27°F) per
1000 m (3280 ft.). Maximum operating altitude is 7000 m (23,000 ft.). Current rating of the SMC-Flex
does not change for altitudes that require a lower maximum ambient temperature.

Mechanical

Operating Temperature Range

-5…+50

°

C (+23…+122

°

F) (open)

-5…+40

°

C (+23…+104

°

F) (enclosed)

Storage and Transportation Temperature
Range

–20…+75

°

C

Altitude

2000 m (6560 ft)

Humidity

5…95% (non-condensing)

Pollution Degree

2

Resistance to
Vibration

Operational All

1.0 G Peak, 0.15 mm (0.006 in.) displacement

Non-Operat
ional

5…480 A

2.5 G, 0.38 mm (0.015 in.) displacement

625…1250 A 1.0 G Peak, 0.15 mm (0.006 in.) displacement

Resistance to
Shock

Operational

5…85 A

15 G

108…480 A

5.5 G

625…1250 A 4 G

Non-Operat
ional

5…85 A

30 G

108…480 A

25 G

625…1250 A 12 G

Construction

Power
Poles

5…85 A

Heatsink thyristor modular design

108…1250 A

Heatsink hockey puck thyristor modular design

Control Modules

Thermoset and Thermoplastic Moldings

Metal Parts

Plated Brass, Copper, or Painted Steel

Terminals

Power
Terminals

5…85 A

Cable size —

Line Upper — 2.5…95 mm

2

(14…3/0 AWG)

Line Lower — 0.8…2.5 mm

2

(18…14 AWG)

Load Upper — 2.5…50 mm

2

(14…1 AWG)

Load Lower — 0.8…2.5 mm

2

(18…14 AWG)

Tightening torque — 14.7 N•m (130 lb.-in.)

Wire strip length — 18…20 mm (0.22…0.34 in.)

108…135 A

One M10 x 1.5 diameter hole per power pole

201…251 A

Two M10 x 1.5 diameter holes per power pole

317…480 A

Two M12 x 1.75 diameter holes per power pole

625…1250 A

Two 13.5 mm (0.53 in.) diameter holes per power

pole

Power Terminal Markings

NEMA, CENELEC EN50 012

Control Terminals

M 3 screw clamp:

clamping yoke connection