Figure 4.2 Parameter Menu Structure

Depending upon SMC option selected, some parameters may not appear in product display.

Steps back one level.

For further information on parameters, see Appendix B.

For further information on parameter management, see page 4-6.

See page 4-4 for all SMC-Flex parameters available by the Linear List.

Parameter

0

Metering

Basic

Overload

Jam

Comm Masks

Language

Linear List

Volts Phase A-B

SMC Option

Overload Class

Jam F Lvl

Logic Mask

Language

All parameters

Volts Phase B-C

Motor Connection

Service Factor

Jam F Dly

Parameter Mgt

Parameter Mgt

Parameter Mgt

Volts Phase C-A

Line Voltage

Motor FLC

Jam A Lvl

Current Phase A

Starting Mode

Overload Reset

Jam A Dly

DataLinks

Motor Data

Current Phase B

Ramp Time

Overload A Lvl

Parameter Mgt

Current Phase C

Initial Torque

Parameter Mgt

Data In A1

MotorFLC

Watt Meter

Cur Limit Lvl

Stall

Data In A2

Motor ID

Kilowatt Hours

Kickstart Time

Underload

Data In B1

Parameter Mgt

Elapsed Time

Kickstart Lvl

Stall Dly

Data In B2

Meter Reset

Stop Input

Underload F Lvl

Parameter Mgt

Data In C1

Power Factor

Option 1 Input

Underload F Dly

Data In C2

Mtr Therm Usage

Option 2 Input

Underload A Lvl

Ground Fault

Data In D1

Motor Speed

Stop Mode

Underload A Dly

Data In D2

Stop Time

Parameter Mgt

Gnd Flt Enable

Data Out A1

Braking Current

Gnd Flt Lvl

Data Out A2

Overload Class

Undervoltage

Gnd Flt Dly

Data Out B1

Service Factor

Gnd Flt Inh Time

Data Out B2

Motor FLC

Undervolt F Lvl

Gnd Flt A Enable

Data Out C1

Overload Reset

Undervolt F Dly

Gnd Flt A Lvl

Data Out C2

Aux1 Config

Undervolt A Lvl

Gnd Flt A Dly

Data Out D1

Aux2 Config

Undervolt A Dly

Parameter Mgt

Data Out D2

Aux3 Config

Parameter Mgt

Parameter Mgt

Aux4 Config

PTC

Backspin Timer

Overvoltage

Parameter Mgt

PTC Enable

Overvolt F Lvl

Parameter Mgt

Dual Ramp (Option
2 Input = Dual
Ramp)

Overvolt F Dly
Overvolt A Lvl

Phase Reversal

Overvolt A Dly

Starting Mode 2

Parameter Mgt

Phase Reversal

Ramp Time 2

Parameter Mtg

Initial Torque 2

Unbalance

Cur Limit Lvl 2

Restart

Kickstart Time 2

Unbalance F Lvl

Kickstart Lvl 2

Unbalance F Dly

Starts Per Hour

Parameter Mgt

Unbalance A Lvl

Restart Attempts

Unbalance A Dly

Restart Dly

Preset SS (Option 2
Input = Preset SS)

Parameter Mgt

Parameter Mtg

Slow Speed Sel
Slow Speed Dir
Slow Accel Cur
Slow Running Cur
Parameter Mgt

(Option 2 Input =
Accu-Stop)
Slow Speed Sel
Slow Accel Cur
Slow Running Cur
Braking Current
Stopping Current
Parameter Mgt

Motor

Set Up

Utility

Linear List

Protection

Parameter

Monitoring

Communications

➀➂

Esc