Figure 4.2 parameter menu structure, Programming 4-3 – Rockwell Automation 150 SMC-Flex User Manual User Manual
Page 87

Programming
4-3
Figure 4.2 Parameter Menu Structure
➀
Depending upon SMC option selected, some parameters may not appear in product display.
➁
Steps back one level.
➂
For further information on parameters, see Appendix B.
➃
For further information on parameter management, see page 4-6.
⑤
See page 4-4 for all SMC-Flex parameters available by the Linear List.
Parameter
0
Metering
Basic
Overload
Jam
Comm Masks
Language
Linear List
Volts Phase A-B
SMC Option
Overload Class
Jam F Lvl
Logic Mask
Language
All parameters
Volts Phase B-C
Motor Connection
Service Factor
Jam F Dly
Parameter Mgt
➃
Parameter Mgt
➃
Parameter Mgt
➃
Volts Phase C-A
Line Voltage
Motor FLC
Jam A Lvl
Current Phase A
Starting Mode
Overload Reset
Jam A Dly
DataLinks
Motor Data
Current Phase B
Ramp Time
Overload A Lvl
Parameter Mgt
➃
Current Phase C
Initial Torque
Parameter Mgt
➃
Data In A1
MotorFLC
Watt Meter
Cur Limit Lvl
Stall
Data In A2
Motor ID
Kilowatt Hours
Kickstart Time
Underload
Data In B1
Parameter Mgt
➃
Elapsed Time
Kickstart Lvl
Stall Dly
Data In B2
Meter Reset
Stop Input
Underload F Lvl
Parameter Mgt
➃
Data In C1
Power Factor
Option 1 Input
Underload F Dly
Data In C2
Mtr Therm Usage
Option 2 Input
Underload A Lvl
Ground Fault
Data In D1
Motor Speed
Stop Mode
Underload A Dly
Data In D2
Stop Time
Parameter Mgt
➃
Gnd Flt Enable
Data Out A1
Braking Current
Gnd Flt Lvl
Data Out A2
Overload Class
Undervoltage
Gnd Flt Dly
Data Out B1
Service Factor
Gnd Flt Inh Time
Data Out B2
Motor FLC
Undervolt F Lvl
Gnd Flt A Enable
Data Out C1
Overload Reset
Undervolt F Dly
Gnd Flt A Lvl
Data Out C2
Aux1 Config
Undervolt A Lvl
Gnd Flt A Dly
Data Out D1
Aux2 Config
Undervolt A Dly
Parameter Mgt
➃
Data Out D2
Aux3 Config
Parameter Mgt
➃
Parameter Mgt
➃
Aux4 Config
PTC
Backspin Timer
Overvoltage
Parameter Mgt
➃
PTC Enable
Overvolt F Lvl
Parameter Mgt
➃
Dual Ramp (Option
2 Input = Dual
Ramp)
Overvolt F Dly
Overvolt A Lvl
Phase Reversal
Overvolt A Dly
Starting Mode 2
Parameter Mgt
➃
Phase Reversal
Ramp Time 2
Parameter Mtg
➃
Initial Torque 2
Unbalance
Cur Limit Lvl 2
Restart
Kickstart Time 2
Unbalance F Lvl
Kickstart Lvl 2
Unbalance F Dly
Starts Per Hour
Parameter Mgt
➃
Unbalance A Lvl
Restart Attempts
Unbalance A Dly
Restart Dly
Preset SS (Option 2
Input = Preset SS)
Parameter Mgt
➃
Parameter Mtg
➃
Slow Speed Sel
Slow Speed Dir
Slow Accel Cur
Slow Running Cur
Parameter Mgt
➃
(Option 2 Input =
Accu-Stop)
Slow Speed Sel
Slow Accel Cur
Slow Running Cur
Braking Current
Stopping Current
Parameter Mgt
➃
Motor
Set Up
Utility
Linear List
⑤
Protection
Parameter
Monitoring
Communications
➀➂
➁
Esc