Refer to, Opening door over power structure and main – Rockwell Automation 5730 DriveLogix5730 Controller for PowerFlex 700S Drives with Phase II Control User Manual
Page 198

B-2
Access Procedures
Opening Door Over Power
Structure and Main Control
Board
Removing the Control
Cassette from Frame 1-6
Size Drives
Frames 1-4
Locate the slot in the upper left corner. Slide
the locking tab up and swing the cover open.
Special hinges allow cover to move away from
drive and lay on top of adjacent drive (if
present).
Frame 5
Slide the locking tab up, loosen the right-hand
cover screw and remove.
Frame 6
Loosen 2 screws at bottom of drive cover.
Carefully slide bottom cover down & out.
Loosen the 2 screws at top of cover and
remove.
a
hw0966.eps
BR1
BR2
DC+
DC-
PE
U/T1
V/T2
W/T3
R/L1
L2
ahw0752.eps
=
esd.eps
Task
Description
Open the door of the power structure and disconnect the cables that
connect to the main board
Loosen screws on face of cassette
Remove the cassette
A
B
C
C
C
B
B
A