DriveLogix5730 Controller
Specifications
DriveLogix5730
Environmental
Specifications
Category
Specification
serial port (CH0 -RS-232)
RS-232, fully isolated
DF1, DH-485, ASCII
38.4 Kbits/s maximum
optional embedded EtherNet/IP
RJ-45 or 100BaseT
10/100 Mbytes/sec
connectivity options
(these options require the Logix
Expansion Board and Expanded
Cassette)
• NetLinx communication daughtercards
(ControlNet, EtherNet/IP, DeviceNet, Third Party)
• Compact I/O connection
• CompactFlash (memory card)
user memory
1.5 Mbyte
nonvolatile memory
1784-CF64 CompactFlash
maximum number of I/O banks
2
maximum number of I/O modules 16 (8 modules per bank)
or
(4 max on either side of the power supply)
battery
1769-BA
serial cable
1756-CP3 directly to controller
1747-CP3 directly to controller
Compact I/O Cable
20D-DL2-CR3
20D-DL2-CL3
Category
Specification
operating temperature
storage temperature
relative humidity
vibration
shock
emissions
Electrical/EMC
CISPA11: Group 1, Class A
ESD Immunity (IEC61000-4-2) The unit has passed testing at the following levels:
Radiated RF Immunity
(IEC61000-4-3)
4 kV contact discharges, 8 kV air discharges
Surge Transient Immunity
(IEC61000-4-5)
10V/M with 1kHz sine-wave 80%AM from 30MHz to 2000MHz
10V/m with 200Hz 50% Pulse 100%AM at 900MHz
Conducted RF Immunity
(IEC61000-4-6)
+1 kV line-line (DM) and +2 kV line-earth (CM) on signal ports