beautypg.com

Rockwell Automation 20L PowerFlex 700L Frame 1X Liquid-Cooled Adjustable Frequency AC Drive User Manual

Page 56

background image

PowerFlex 700L Frame 1X Drive Installation Instructions – Publication 20L-IN013A-EN-P – June 2009

56

Environment
(continued)

Relative Humidity:

5…95% non-condensing

Shock:

40G peak for 6 milliseconds duration (

±

3.0 ms)

Vibration:

Sinusoidal:

Random:

0.35 mm (0.014 in.) constant displacement to a

constant acceleration of 5G.
10…500 Hz, 1 octave/minute, 10 sweep cycles,
3 axes

0.05 g

2

/Hz, 10…500 Hz, 3 axes at 30 minutes per

axis

Electrical

Input Voltage:

480V RMS, +10%, -5% (operate to -50% with
reduced power, -30% minimum precharge)
Note: The PowerFlex Frame 1X drive requires a
3% input impedance.

Input Frequency Range:

47…63 Hz.

Line-to-Neutral Phase
Imbalance Tolerance:

2%

Output Voltage:

0…460V RMS at nominal 480V RMS input. Output
will be 460V RMS.

Output Frequency Range:

0…420 Hz

Switching Frequency:

4 kHz base; 2, 4, 8, 10 kHz selectable with
derating. Derating at 8 and 10 kHz.

Continuous Output Power:

100 kW (150 HP)

Continuous Output Current:

180 amps RMS

Peak Output Current:

3 seconds Maximum:
1 minute:

270 amps RMS (3 seconds per 60 seconds)
198 amps RMS (1 minute per 10 minutes)

Efficiency at Maximum Power,
Nominal Voltage:

> 97.5%

Power Loss at Full Load:

1900 W at 100 kW

Power Loss to Air:

200 W at 110 kW

Control

Method:

Sine-coded PWM with programmable carrier
frequency.

Carrier Frequency:

2…10 kHz. Drive rating based on 4 kHz.

Derate Guidelines on page 58

for more

information.

Output Voltage Range:

0…rated motor voltage

Output Frequency Range:

0…420 Hz

Frequency Accuracy

Digital Input:
Analog Input:

Within ± 0.01% of set output frequency.
Within ± 0.4% of maximum output frequency

Frequency Control:

Speed Regulation - with Slip Compensation (Volts
per Hertz Mode)

0.5% of base speed across 40:1 speed range
40:1 operating range
10 rad/sec bandwidth

Speed Regulation - with Slip Compensation
(Sensorless Vector Mode)

0.5% of base speed across 80:1 speed range
80:1 operating range
20 rad/sec bandwidth

Speed Regulation - with Feedback (Sensorless
Vector Mode)

0.1% of base speed across 80:1 speed range
80:1 operating range
20 rad/sec bandwidth

Category