19

Figure 6

Power Terminal Locations

Table 5

Power Terminal Specifications

Power Wiring

R

S

T

U

T1

V

T2

W

T3

OUTPUT

Item Name

Description

Wire Size Range

(1)

(1)

Maximum/minimum sizes that the terminal block will accept - these are not recommendations.

Recommended
Torque (
±10%)

Terminal
Bolt Size

Maximum

Minimum

Input
Power

R (L1), S (L2), and T (L3)
connections

70 mm

2

(2/0 AWG)

50 mm

2

(1 AWG)

7.9 N•m
(70 lb•in)

M6

Output
Power

U (T1), V (T2), and W (T3)
connections

70 mm

2

(2/0 AWG)

50 mm

2

(1 AWG)

3.95 N•m
(35 lb•in)

M5

Brake
Resistor

BR1 (DC Brake +) and BR2
(DC Brake -) connections

35 mm

2

(2 AWG)

25 mm

2

(4 AWG)

3.95 N•m
(35 lb•in)

M5

Ground

PE and motor ground
connections

70 mm

2

(2/0 AWG)

50 mm

2

(1 AWG)

7.9 N•m
(70 lb•in)

M6