Figure 10

shows the drive Main Control Board and its terminal block

locations. The Main Control Board includes the drive control firmware, I/O
terminal block, and optional encoder board.

Figure 10

Drive Main Control Board and I/O Control Terminal Blocks

Table 8

I/O Terminal Block Specifications

I/O Terminals

T

BR1

S

R

Pin 1

Main Control Board

Terminal Details

Pin 1

No. Name

Description

Wire Size Range

(1)

(1)

Maximum/minimum that the terminal block will accept - these are not recommendations.

Torque

Maximum

Minimum

Maximum

Recommended

I/O Terminal Block Signal and control

connections

2.1 mm

2

(14 AWG)

0.30 mm

2

(22 AWG)

0.6 N•m
(5.2 lb•in)

0.6 N•m
(5.2 lb•in)

Encoder (optional)
Terminal Block

Encoder power and
signal connections

0.75 mm

2

(18 AWG)

0.196 mm

2

(24 AWG)

0.6 N•m
(5.2 lb•in)

0.6 N•m
(5.2 lb•in)